“This site contains affiliate links for which OEMDTC may be compensated” |
April 20, 2022 NHTSA CAMPAIGN NUMBER: 22V268000
Electrical Relay May Overheat and Cause Fire
An overheated electrical relay increases the risk of a fire.
NHTSA Campaign Number: 22V268
Manufacturer Kibbi, LLC
Components ELECTRICAL SYSTEM
Potential Number of Units Affected 148
Summary
Kibbi, LLC (Kibbi) is recalling certain 2021 Renegade RV Vienna and Villagio motorhomes equipped with Dayton/Snyder electrical relays. A stranded wire used in the connector may cause the relay to overheat.
Remedy
Dealers will remove the electrical relay and reconnect wiring as necessary. Dealers will also add a warning label by the Firefly touch screen that states, “Don’t use Range, Microwave or Air Conditioning unit unless the coach is powered by shore or Generator.” All repairs will be performed free of charge. Owner notification letters are expected to be mailed on April 29, 2022. Owners may contact Kibbi’s customer service at 1-574-966-0196.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.nhtsa.gov.
This notice is sent to you in accordance with the National Traffic and Motor Vehicle Safety Act.
Renegade RV has decided that a defect, which relates to motor vehicle safety, exists in certain 2021 Vienna/Villagio vehicles. Upon receipt of this notice contact your local service center to schedule an appointment to have the remedy performed. Renegade RV will execute this remedy (0.5 labor hours allotted for relay only). The service center is to order the part kit (# 4520068) that Renegade RV will supply at NO CHARGE and complete the repair for free.
What is the issue: Possibility for a fire at the 110 VAC load center due to heat from the Dayton/Snyder Electric relay.
What is the safety risk: The possibility of the 110 VAC load center and or the DAYTON/Snyder Electric relay distorting, melting and up to causing a fire.
Identify any warning which can precede or occur: Possibility of smell and/or smoke.
What is the cause: Stranded wire used in a compression style connector causing heat within the relay.
What is the Remedy: At no cost to the customer, Renegade will remove jumper wire from Dayton/Snyder Electric relay to main breaker. Move S.J. wire from Dayton/Snyder Electric relay to main breaker. Remove the Dayton/Snyder Electric relay, remove 12 VDC trigger wires from the 110 VAC load center with the relay, cap off 12 VDC wires, using bell connectors, and secure behind load center with zip tie. Add decal by Firefly touch screen indicating “Don’t use Range, Microwave or Air Conditioning unit unless coach is powered by shore or Generator” The Dayton/Snyder Electric relay does not allow for the range, microwave, or A/C to operate off the inverter by sensing shore/generator power through the transfer switch.
Removal of the relay will allow the range, microwave, and A/C to operate on the inverter. Customer to be made aware of load management with this change.
If you have incurred expense to remedy this issue prior to the date of this notice, you may have the opportunity to obtain reimbursement for that expense. For details, contact us at the number or email address provided.
warranty@renegaderv.com
Jaxon Prill-574-966-0166
John Wood-574-966-0193
If you believe that Renegade RV has failed, or is unable to remedy this defect without charge and within a reasonable amount of time, you may submit a complaint to the Administrator, National Highway Traffic Safety Administration, 1200 New Jersey Avenue, S.E. Washington DC 20590; or call the toll free Vehicle Safety Hotline at 1-888-327-4236 (TTY: 1-800-424-9153); or go to http://www.safecar.gov.
Renegade RV is committed to providing the best products that enable our customers to enjoy a mobile lifestyle and we apologize for any inconvenience this may cause.
Chronology :
9/14/2021- Retail customer K34-1607 reached out for faulty relay.
9/15/2021-Relay ordered from vendor
9/21/2021-Relay received, sent to dealer for repair.0-deaths 0-injuries
11/8/2021- Retail customer K14-0477 reached out for heat related damaged to relay
11/9/2021- Research relay, order new 110VAC load center without relay
11/22/2021- Received 110 VAC load center, sent to dealer for repair 0Deaths 0-injuries
1/6/2022- Dealer reached out for heat related damage to relay for K14-0503
1/7/2022- New 110 VAC load center, without relay, sent out to dealer for repair 0-Deaths 0-injuries
3/23/2022-Dealer reached out for heat related damage to relay for K34-1494
3/23/2022- New 110 VAC load center, without relay, sent to dealer for repair 0-deaths 0-injuries
2 Affected Products
Vehicles
MAKE | MODEL | YEAR |
RENEGADE | VIENNA | 2021 |
RENEGADE | VILLAGIO | 2021 |
9 Associated Documents
Recall Acknowledgement
Defect Notice 573 Report
RCLRPT-22V268-9068.PDF 213.574KB
Recall 573 Report- 05/02/2022
RCLRPT-22V268-7661.PDF 216.1KB
Recall 573 Report- 06/02/2022
RCLRPT-22V268-3039.PDF 216.084KB
Recall Quarterly Report #1, 2022-2
RCLQRT-22V268-1660.PDF 211.127KB
Recall Quarterly Report #2, 2022-3
RCLQRT-22V268-9342.PDF 211.222KB
Recall Quarterly Report #3, 2022-4
RCLQRT-22V268-1772.PDF 211.312KB
Owner Notification Letter(Part 577)
RCONL-22V268-2688.pdf 295.335KB
Recall Quarterly Report #4, 2023-1
RCLQRT-22V268-3456.PDF 211.412KB
Latest Recalls Documents
For the Latest and Most Recent Recalls Information Visit the link below…
https://www-odi.nhtsa.dot.gov/acms/cs/documentList.xhtml?docId=22V268&docType=RCL
- Never go beyond its capabilities. Try to stay 10 to 15% below what the rate is for
- 12-volt 5-prong relay. Excellent water-repellent and dustproof ability, but not using it in water
- Be careful when inserting the relay into the socket. If you force it, you will bend the female connectors
- Primary leads use 12 a.w.g tinned copper wire. Coil leads use 16 a.w.g
- Nominal Coil Voltage: 12 V DC; Coil Power: 1.8 W; Coil Resistance: 80 Ω; Must Operate Voltage: 6~8 V DC; Must Release Voltage: 0.6~3.6 V DC; Maximum Applied Voltage: 15.6 V DC
- High switching capability: Normally open 40A/14V DC and normally close 30A/14V DC. Suitable for Nilight LED light bar wiring harness kit
- Premium quality: Durable relay and harness socket with 5 wires; Made by high-grade materials to ensure superior quality and long lifespan
- Male-female slot design: Unique male-female slot design, easy to connect the relay with harness socket, clean and neat after installation
- Easy wiring: The relay sockets come with different colors for loads/accessories, simple and convenient wiring
- Package include: 5 x relay and 5 x relay socket with wires.Fit type: Universal fit
- Assembled Relay Fuse Box: This automotive 12v relay box with wiring harness has high capacity holder box, package includes 5pcs 4Pin 40A JD1914 Relays and 1pcs 4 Pin RTT7121 Relay, 6pcs 5A, 10A, 15A, 20A, 25A, 30A blade fuses.
- Solid Material: Joinfworld 12V Fuse and Relay Box is made of high-quality nylon material flame retardant shell, each slot has a precise cutout, and an arc socket is reserved on the edge, so that all your wiring is neat and beautiful.
- Neat Wiring Harness: This 12v car relay fuse box has all the necessary wires pre-wired so you can connect directly to the vehicle, avoiding the hassle of wiring, it is more convenient for your installation and use.
- High performance: Joinfworld 12V Fuse and Relay Box comes with functional powerful insulation shell, with waterproof and dust-proof top cover and bottom cover, wire opening hole is the outlet of all wires, which can be well connected together for better waterproof dust fire prevention.
- Wide Application: The Automotive Relay Box suitable for all vehicles, 4X4 Offroad Jeep SUV UTV ATV RV Pickup Truck Trailer Camper Marine Boat, etc. For any problems, please do not hesitate to write to us.
- Brand new heavy duty SPST(Single Pole Single Throw) relays with color-labeled wires.
- Minimum operating voltage 8V, corresponding minimum operating current is 100mA; Standard operating voltage 12V, corresponding standard operating current is 150mA.
- Small size/Low power consumption/High contact voltage/ High sensitivity.
- Contact Material: Ag Alloy / Contact Resistance: ≤ 100MΩ.
- Life Expectancy Electrical: 100,000 Operation, Life Expectancy Mechanical: 10,000,000 Operation.
- Upgraded Version - Automotive relays built in fuse socket included 30A blade fuses with heavy duty 14AWG wires for main contact. No need of a separate fuse holder, saving space and money. Bosch style 4-Pin SPST (Single Pole Single Throw) Relay.
- Mounting Design Feature - The interlocking mounting design of unique male and female slot on each socket edge, connect relays together and manage cables easily, offering clean and neat installation.
- Easy Wiring - The relay sockets come with color-labeled wires for load/accessories convenient wiring. Black - Ground (85), Red - VDC (30), White - Trigger (86), Blue - Output N/O (87)
- Wide Application - Widely used in car keys power control, over-load protection, trunk release, polarity change, power door lock/actuator control, change a low current output to high current, add ignition/accessory outputs, control motors/other electronics etc.
- Set includes 5 relays, 5 relay harnesses, and 5 30A blade fuses. 2 Year Warranty by Nilight.
- Quality Materials: The shell is made of PA66 material and pure copper enameled wire, which has good thermal conductivity, can dissipate heat faster and reduce temperature rise. The compact and repairable structure of the sloped trim relay will hardly break or deform, helping you adjust and switch circuits stably.
- Plug and Play: Compatible with the most universal 12V 5-Pin automotive relay with a 40A switching capability. Easy to process your demand. Please check the dimensions and the direction of the poles carefully before ordering to avoid buying the incorrect product.
- Wide Application: Outboard tilt system application and all automotive devices equipped with a 12-volt dc power source car sound systems, security systems, compressor, air.
- Nice Replacement for Many Relays: The electrical relay box can be a nice replacement for 582195, 582472, 582473, 584416, 586147 and 586224, offering you a pleasant using experience.
- Sufficient Quantity for Using: The package comes with 4 pieces of automotive replacement electrical system relays, enough to meet your using and replacing demands in daily life, bringing you lots of convenience.
- 12V waterproof 5-Pin SPDT Relay Excellent waterproof and dustproof ability, high quality in any weather conditions
- 12V 5-Pin SPDT Relay Pin Specifications: Ground (85), VDC (30), Trigger (86), Output N/C (87a), and Output N/O (87).
- SPDT Relay with 40A/30A High Switching Capability,it has both normally open and normally closed terminals, terminal 87A is powered when the relay is inactive and switches the power to terminal 87 when the relay is activated.
- 12v relays can operate with anywhere between 9v and 14v,Very suitable for 12V automotive, marine, and machine circuits.
- These 12V 5-pin relays are rated to handle 30A on normally closed pin 87a and 40A on normally open pin 87.
- Built in fuse socket with included 30A blade fuse with heavy duty 14AWG wires for main contact.
- Bosch style 4-Pin SPST (Single Pole Single Throw) Relay.
- 12VDC (14V Max) and 30A High Switching Capability.
- Wire Specifications: Black - Ground (85), Red - VDC (30), White - Trigger (86), Blue - Output N/O (87).
- Set includes 6 relays, 6 relay harnesses, and 6 blade fuses.
- Heavy duty 4-prongs SPST relays, jd1912 12v 40a relay
- Use optional Relay Harness, or female Crimp Connectors
- High 40A coil capacity- able to handle those high current applications with ease
- Package Include: 2 x 40A 4-Pin 12V Vehicle Relays
- The Automotive relay is suitable for normal automobile use and simple to operate, you just need to connect the relay with the wire, no other tools needed, convenient for your use and replace, allowing your components to work properly
- User Manual available for download under Product Information Details
- Bosch style 12VDC (14V Max) 5-Pin SPDT (Single Pole Double Throw) Relay with 40A/30A High Switching Capability.
- Interlocking design relay socket harness base for easy cable management & organization.
- Heavy duty 14AWG wires for the main contact and pre-wired with 6" pigtail leads.
- Wire Specifications: Black - Ground (85), Red - VDC (30), White - Trigger (86), Yellow - Output N/C (87a), and Blue - Output N/O (87).
Last update on 2024-04-12 / Affiliate links / Images from Amazon Product Advertising API
This product presentation was made with AAWP plugin.
SEOCONTENT-START
IKON Verona XL Valencia Classic Veracruz Explorer Vienna Verona LE Villagio Renegade RV February 8, 2023 Page 1 IMPORTANT SAFETY RECALL Renegade RV Recall Campaign 22V268 February 28,2022 THIS NOTICE APPLIES TO YOUR VEHICLE Renegade RV 52216 State Road 15 Bristol, IN 46507 February 28, 2022 Attention: Renegade Owner This notice pertains to Vin. # Unit # This notice is sent to you in accordance with the National Traffic and Motor Vehicle Safety Act. Renegade RV has decided that a defect, which relates to motor vehicle safety, exists in certain 2021 Vienna/Villagio vehicles. Upon receipt of this notice contact your local service center to schedule an appointment to have the remedy performed. Renegade RV will execute this remedy (0.5 labor hours allotted for relay only). The service center is to order the part kit (# 4520068) that Renegade RV will supply at NO CHARGE and complete the repair for free. What is the issue: Possibility for a fire at the 110 VAC load center due to heat from the Dayton/Snyder Electric relay. What is the safety risk: The possibility of the 110 VAC load center and or the DAYTON/Snyder Electric relay distorting, melting and up to causing a fire. Identify any warning which can precede or occur: Possibility of smell and/or smoke. What is the cause: Stranded wire used in a compression style connector causing heat within the relay. What is the Remedy: At no cost to the customer, Renegade will remove jumper wire from Dayton/Snyder Electric relay to main breaker. Move S.J. wire from Dayton/Snyder Electric relay to main breaker. Remove the Dayton/Snyder Electric relay, remove 12 VDC trigger wires from the 110 VAC load center with the relay, cap off 12 VDC wires, using bell connectors, and secure behind load center with zip tie. Add decal by Firefly touch screen indicating ““Don’t use Range, Microwave or Air Conditioning unit unless coach is powered by shore or Generator” The Dayton/Snyder Electric relay does not allow for the range, microwave, or A/C to operate off the inverter by sensing shore/generator power through the transfer switch. IKON Verona XL Valencia Classic Veracruz Explorer Vienna Verona LE Villagio Renegade RV February 8, 2023 Page 2 Removal of the relay will allow the range, microwave, and A/C to operate on the inverter. Customer to be made aware of load management with this change. If you have incurred expense to remedy this issue prior to the date of this notice, you may have the opportunity to obtain reimbursement for that expense. For details, contact us at the number or email address provided. warranty@renegaderv.com Jaxon Prill-574-966-0166 John Wood-574-966-0193 If you believe that Renegade RV has failed, or is unable to remedy this defect without charge and within a reasonable amount of time, you may submit a complaint to the Administrator, National Highway Traffic Safety Administration, 1200 New Jersey Avenue, S.E. Washington DC 20590; or call the toll free Vehicle Safety Hotline at 1-888-327-4236 (TTY: 1-800-424-9153); or go to http://www.safecar.gov. Renegade RV is committed to providing the best products that enable our customers to enjoy a mobile lifestyle and we apologize for any inconvenience this may cause. Best regards, Kirk Manring Customer Service Manager Renegade Mfg. Office: 574-966-0160 kmanring@renegaderv.com
**************************************************************************************************************
OMB Control No.: 2127-0004 Part 573 Safety Recall Report 22V-268 The information contained in this report was submitted pursuant to 49 CFR §573 Manufacturer Name : Submission Date : Kibbi, LLC APR 20, 2022 NHTSA Recall No. : 22V-268 Manufacturer Recall No. : NR Manufacturer Information : Manufacturer Name : Kibbi, LLC Address : 52218 State Route 15 Bristol IN 46507 Company phone : 574-966-0196 Population : Number of potentially involved : NR Estimated percentage with defect : NR Vehicle Information : Vehicle 1 : 2021-2021 Renegade Rv Vienna,Villagio Vehicle Type : Body Style : Power Train : NR Descriptive Information : Remove Dayton/Snyder Electric relay from the 110 VAC load center due to the possibility of a thermal event due to stranded wire used in a compression style connector, on the relay, creating heat in the relay. Relay only used in this product for this time period. 148 units affected Production Dates : MAR 24, 2021 – NOV 02, 2021 VIN Range 1 : Begin : NR End : NR Not sequential Description of Defect : Description of the Defect : Possibility for a thermal event at the 110 VAC load center due to heat from the Dayton/Snyder Electric relay. FMVSS 1 : NR FMVSS 2 : NR Description of the Safety Risk : The possibility of the 110 VAC load center and or the DAYTON/Snyder Electric relay distorting, melting and up to a thermal event. Description of the Cause : Stranded wire used in a compression style connector causing heat within the relay. Identification of Any Warning that can Occur : Possibility of smell and/or smoke Involved Components : Part 573 Safety Recall Report 22V-268 Page 2 Component Name 1 : NR Component Description : NR Component Part Number : NR Supplier Identification : Component Manufacturer Name : NR Address : NR NR Country : NR Chronology : 9/14/2021- Retail customer K34-1607 reached out for faulty relay. 9/15/2021-Relay ordered from vendor 9/21/2021-Relay received, sent to dealer for repair. 11/8/2021- Retail customer K14-0477 reached out for heat related damaged to relay 11/9/2021- Research relay, order new 110VAC load center without relay 11/22/2021- Received 110 VAC load center, sent to dealer for repair 1/6/2022- Dealer reached out for heat related damage to relay for K14-0503 1/7/2022- New 110 VAC load center, without relay, sent out to dealer for repair 3/23/2022-Dealer reached out for heat related damage to relay for K34-1494 3/23/2022- New 110 VAC load center, without relay, sent to dealer for repair The information contained in this report was submitted pursuant to 49 CFR §573 Part 573 Safety Recall Report 22V-268 Page 3 The information contained in this report was submitted pursuant to 49 CFR §573 Description of Remedy : Description of Remedy Program : At no cost to the customer, Renegade will remove jumper wire from Dayton/Snyder Electric relay to main breaker. Move S.J. wire from Dayton/Snyder Electric relay to main breaker. Remove the Dayton/Snyder Electric relay, remove 12 VDC trigger wires from the 110 VAC load center with the relay, cap off 12 VDC wires, using bell connectors, and secure behind load center with zip tie. Add decal by Firefly touch screen indicating ““Don’t use Range, Microwave or Air Conditioning unit unless coach is powered by shore or Generator” The Dayton/Snyder Electric relay does not allow for the range, microwave, or A/C to operate off the inverter by sensing shore/generator power through the transfer switch. Removal of the relay will allow the range, microwave, and A/C to operate on the inverter. Customer to be made aware of load management with this change. How Remedy Component Differs from Recalled Component : Identify How/When Recall Condition was Corrected in Production : Relay is removed similar to current production standards Dayton/Snyder Electric relay removed starting 11/03/2021 Recall Schedule : Description of Recall Schedule : NR Planned Dealer Notification Date : APR 29, 2022 – JUN 04, 2022 Planned Owner Notification Date : APR 29, 2022 – JUN 04, 2022 * NR – Not Reported
**************************************************************************************************************
OMB Control No.: 2127-0004 Part 573 Safety Recall Report 22V-268 The information contained in this report was submitted pursuant to 49 CFR §573 Manufacturer Name : Submission Date : Kibbi, LLC MAY 02, 2022 NHTSA Recall No. : 22V-268 Manufacturer Recall No. : NR Manufacturer Information : Manufacturer Name : Kibbi, LLC Address : 52218 State Route 15 Bristol IN 46507 Company phone : 574-966-0196 Population : Number of potentially involved : 146 Estimated percentage with defect : 100 % Vehicle Information : Vehicle 1 : 2021-2021 Renegade Rv Vienna,Villagio Vehicle Type : BUSES, MEDIUM & HEAVY VEHICLES Body Style : OTHER Power Train : DIESEL Descriptive Information : Remove Dayton/Snyder Electric relay from the 110 VAC load center due to the possibility of a thermal event due to stranded wire used in a compression style connector, on the relay, creating heat in the relay. Relay only used in this product for this time period. 148 units affected Production Dates : MAR 24, 2021 – NOV 02, 2021 VIN Range 1 : Begin : W1X8E33Y3LN127761 End : W1X8E33Y9MN161205 VIN Range 2 : Begin : W1X8E33Y3LN127761 End : W1X8E33Y9MN161205 VIN Range 3 : Begin : W1X8E33Y3LN127761 End : W1X8E33Y9MN161205 VIN Range 4 : Begin : W1X8E33Y3LN127761 End : W1X8E33Y9MN161205 VIN Range 5 : Begin : W1X8E33Y3LN127761 End : W1X8E33Y9MN161205 VIN Range 6 : Begin : W1X8E33Y3LN127761 End : W1X8E33Y9MN161205 VIN Range 7 : Begin : W1X8E33Y3LN127761 End : W1X8E33Y9MN161205 VIN Range 8 : Begin : W1X8E33Y3LN127761 End : W1X8E33Y9MN161205 VIN Range 9 : Begin : W1X8E33Y3LN127761 End : W1X8E33Y9MN161205 ✔ Not sequential ✔ Not sequential ✔ Not sequential ✔ Not sequential ✔ Not sequential ✔ Not sequential ✔ Not sequential ✔ Not sequential ✔ Not sequential Description of Defect : Description of the Defect : Possibility for a thermal event at the 110 VAC load center due to heat from the Dayton/Snyder Electric relay. FMVSS 1 : NR FMVSS 2 : NR Description of the Safety Risk : The possibility of the 110 VAC load center and or the DAYTON/Snyder Electric relay distorting, melting and up to a thermal event. Part 573 Safety Recall Report 22V-268 Page 2 Description of the Cause : Stranded wire used in a compression style connector causing heat within the relay. Identification of Any Warning that can Occur : Possibility of smell and/or smoke Involved Components : Component Name 1 : Dayton/Snyder electric relay Component Description : Solid state relay-3 to 32V DC-EL1EGK4- Component Part Number : 98546 Supplier Identification : Component Manufacturer Name : Renegade RV Address : 52216 State Road 15 Bristol 46507 Country : United States Chronology : 9/14/2021- Retail customer K34-1607 reached out for faulty relay. 9/15/2021-Relay ordered from vendor 9/21/2021-Relay received, sent to dealer for repair.0-deaths 0-injuries 11/8/2021- Retail customer K14-0477 reached out for heat related damaged to relay 11/9/2021- Research relay, order new 110VAC load center without relay 11/22/2021- Received 110 VAC load center, sent to dealer for repair 0Deaths 0-injuries 1/6/2022- Dealer reached out for heat related damage to relay for K14-0503 1/7/2022- New 110 VAC load center, without relay, sent out to dealer for repair 0-Deaths 0-injuries 3/23/2022-Dealer reached out for heat related damage to relay for K34-1494 3/23/2022- New 110 VAC load center, without relay, sent to dealer for repair 0-deaths 0-injuries The information contained in this report was submitted pursuant to 49 CFR §573 Part 573 Safety Recall Report 22V-268 Page 3 The information contained in this report was submitted pursuant to 49 CFR §573 Description of Remedy : Description of Remedy Program : At no cost to the customer, Renegade will remove jumper wire from Dayton/Snyder Electric relay to main breaker. Move S.J. wire from Dayton/Snyder Electric relay to main breaker. Remove the Dayton/Snyder Electric relay, remove 12 VDC trigger wires from the 110 VAC load center with the relay, cap off 12 VDC wires, using bell connectors, and secure behind load center with zip tie. Add decal by Firefly touch screen indicating ““Don’t use Range, Microwave or Air Conditioning unit unless coach is powered by shore or Generator” The Dayton/Snyder Electric relay does not allow for the range, microwave, or A/C to operate off the inverter by sensing shore/generator power through the transfer switch. Removal of the relay will allow the range, microwave, and A/C to operate on the inverter. Customer to be made aware of load management with this change. How Remedy Component Differs from Recalled Component : Identify How/When Recall Condition was Corrected in Production : Relay is removed similar to current production standards Dayton/Snyder Electric relay removed starting 11/03/2021 Recall Schedule : Description of Recall Schedule : Letter to customer will sent via mail starting 4/29/2022 will proceed through 5/13/2022. Dealer letters will be sent with recall kit. Planned Dealer Notification Date : APR 29, 2022 – JUN 04, 2022 Planned Owner Notification Date : APR 29, 2022 – JUN 04, 2022 * NR – Not Reported
**************************************************************************************************************
OMB Control No.: 2127-0004 Part 573 Safety Recall Report 22V-268 The information contained in this report was submitted pursuant to 49 CFR §573 Manufacturer Name : Submission Date : Kibbi, LLC JUN 02, 2022 NHTSA Recall No. : 22V-268 Manufacturer Recall No. : NR Manufacturer Information : Manufacturer Name : Kibbi, LLC Address : 52218 State Route 15 Bristol IN 46507 Company phone : 574-966-0196 Population : Number of potentially involved : 146 Estimated percentage with defect : 100 % Vehicle Information : Vehicle 1 : 2021-2021 Renegade Rv Vienna,Villagio Vehicle Type : BUSES, MEDIUM & HEAVY VEHICLES Body Style : OTHER Power Train : DIESEL Descriptive Information : Remove Dayton/Snyder Electric relay from the 110 VAC load center due to the possibility of a thermal event due to stranded wire used in a compression style connector, on the relay, creating heat in the relay. Relay only used in this product for this time period. 148 units affected Production Dates : MAR 24, 2021 – NOV 02, 2021 VIN Range 1 : Begin : W1X8E33Y3LN127761 End : W1X8E33Y9MN161205 VIN Range 2 : Begin : W1X8E33Y3LN127761 End : W1X8E33Y9MN161205 VIN Range 3 : Begin : W1X8E33Y3LN127761 End : W1X8E33Y9MN161205 VIN Range 4 : Begin : W1X8E33Y3LN127761 End : W1X8E33Y9MN161205 VIN Range 5 : Begin : W1X8E33Y3LN127761 End : W1X8E33Y9MN161205 VIN Range 6 : Begin : W1X8E33Y3LN127761 End : W1X8E33Y9MN161205 VIN Range 7 : Begin : W1X8E33Y3LN127761 End : W1X8E33Y9MN161205 VIN Range 8 : Begin : W1X8E33Y3LN127761 End : W1X8E33Y9MN161205 VIN Range 9 : Begin : W1X8E33Y3LN127761 End : W1X8E33Y9MN161205 ✔ Not sequential ✔ Not sequential ✔ Not sequential ✔ Not sequential ✔ Not sequential ✔ Not sequential ✔ Not sequential ✔ Not sequential ✔ Not sequential Description of Defect : Description of the Defect : Possibility for a thermal event at the 110 VAC load center due to heat from the Dayton/Snyder Electric relay. FMVSS 1 : NR FMVSS 2 : NR Description of the Safety Risk : The possibility of the 110 VAC load center and or the DAYTON/Snyder Electric relay distorting, melting and up to a thermal event. Part 573 Safety Recall Report 22V-268 Page 2 Description of the Cause : Stranded wire used in a compression style connector causing heat within the relay. Identification of Any Warning that can Occur : Possibility of smell and/or smoke Involved Components : Component Name 1 : Dayton/Snyder electric relay Component Description : Solid state relay-3 to 32V DC-EL1EGK4- Component Part Number : 98546 Supplier Identification : Component Manufacturer Name : Patrick Industries Address : NR NR Country : United States Chronology : 9/14/2021- Retail customer K34-1607 reached out for faulty relay. 9/15/2021-Relay ordered from vendor 9/21/2021-Relay received, sent to dealer for repair.0-deaths 0-injuries 11/8/2021- Retail customer K14-0477 reached out for heat related damaged to relay 11/9/2021- Research relay, order new 110VAC load center without relay 11/22/2021- Received 110 VAC load center, sent to dealer for repair 0Deaths 0-injuries 1/6/2022- Dealer reached out for heat related damage to relay for K14-0503 1/7/2022- New 110 VAC load center, without relay, sent out to dealer for repair 0-Deaths 0-injuries 3/23/2022-Dealer reached out for heat related damage to relay for K34-1494 3/23/2022- New 110 VAC load center, without relay, sent to dealer for repair 0-deaths 0-injuries The information contained in this report was submitted pursuant to 49 CFR §573 Part 573 Safety Recall Report 22V-268 Page 3 The information contained in this report was submitted pursuant to 49 CFR §573 Description of Remedy : Description of Remedy Program : At no cost to the customer, Renegade will remove jumper wire from Dayton/Snyder Electric relay to main breaker. Move S.J. wire from Dayton/Snyder Electric relay to main breaker. Remove the Dayton/Snyder Electric relay, remove 12 VDC trigger wires from the 110 VAC load center with the relay, cap off 12 VDC wires, using bell connectors, and secure behind load center with zip tie. Add decal by Firefly touch screen indicating ““Don’t use Range, Microwave or Air Conditioning unit unless coach is powered by shore or Generator” The Dayton/Snyder Electric relay does not allow for the range, microwave, or A/C to operate off the inverter by sensing shore/generator power through the transfer switch. Removal of the relay will allow the range, microwave, and A/C to operate on the inverter. Customer to be made aware of load management with this change. How Remedy Component Differs from Recalled Component : Identify How/When Recall Condition was Corrected in Production : Relay is removed similar to current production standards Dayton/Snyder Electric relay removed starting 11/03/2021 Recall Schedule : Description of Recall Schedule : Letter to customer will sent via mail starting 4/29/2022 will proceed through 5/13/2022. Dealer letters will be sent with recall kit. Planned Dealer Notification Date : APR 29, 2022 – JUN 04, 2022 Planned Owner Notification Date : APR 29, 2022 – JUN 04, 2022 * NR – Not Reported
SEOCONTENT-END