“This site contains affiliate links for which OEMDTC may be compensated” |
February 3, 2022 NHTSA CAMPAIGN NUMBER: 22E006000
Helmets May Not Protect From Impact/FMVSS 218
A helmet that does not provide adequate impact protection increases the risk of injury during a crash.
NHTSA Campaign Number: 22E006
Manufacturer Nexxpro – Fabrica de Capacetes, S.A.
Components EQUIPMENT
Potential Number of Units Affected 12
Summary
Nexxpro-Fabrica de Capacetes, S.A. (Nexxpro) is recalling certain X.R2 motorcycle helmets, part number 01XR22312455100M, in size M. Due to a manufacturing error, the helmets may not adequately protect the wearer in the event of a head impact during a crash. As such, these helmets fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 218, “Motorcycle Helmets.”
Remedy
Nexxpro will notify owners and replace the helmets, free of charge. Nexxpro is working on identifying affected owners. Owners may contact Nexxpro customer service at 1-800-461-1226.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.nhtsa.gov.
PRODUCT SAFETY RECALL
NEXX X.R2 MOTORCYCLE HELMET
[CARBON ZERO- serial numbers – 2019-99655 / 2019-99662 / 2019-99658 / 2019-99673 I 2019-99514 I 2019-99517 I 2019-99602 I 2019-99600 I 2019-99533 / 2019-99691 I 2019-99692 I 2019-99598]
[Helmets with manufacturing date from January 2019 to May 2019}
Defect: [Nexxpro-Fabrica de CapacetesJ S.A. (Nexxpro) is recalling certain X.R2 motorcycle helmets/ part number 01XR22312455100MJ in size M. Due to a manufacturing error/ the helmets may not adequately protect the wearer in the event of a head impact during a crash.
As such these helmets fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 218J “Motorcycle Helmets.”]
Hazard: [A helmet that does not provide adequate impact protection increases the risk of injury during a crash.].
What to do: [Nexxpro will notify owners and replace the helmets/ free of charge].
Contact details: [Owners can access the remedy and/or further information on the recan and with no related costs].
Chronology :
Once reported the failure detected during a Safety Compliance Testing for FMVSS No. 218 Motorcycle Helmets (dated 10 Sep 2020), it were picked some parts (of the same batch and also from another batch – 02) and submitted to testing, in an external lab. All of the tested parts were conforming.
Details of the samples submitted to testing:
– Laboratory: Omega (Italy); testing date: 02 Oct 2020; Report Nexxpro XR2 DOT 06102020 – batch 01
– Laboratory: Omega (Italy); testing date: 02 Oct 2020; Report Nexxpro XR2 DOT 06102020-1 – batch 02
It was requested info (S/N) regarding the S/N of the tested samples that failed. With those S/N it was possible to find out part’s history.
According part’s history records, those 12 parts were all submitted to a rework process and, in all of them, it was the same worker who proceeded with the rework and, at least in 11 of the 12 parts, a different raw material (carbon layer) than the specified one was used, and so we do consider as potential affected parts the 12 described.
1 Affected Product
Equipment
BRAND | PART NO. | PRODUCTION DATES |
NEXX | X.R2 MOTORCYCLE HELMET |
11 Associated Documents
Recall Acknowledgement
RCAK-22E006-9909.pdf 645.544KB
Noncompliance Notice 573 Report
RCLRPT-22E006-7856.PDF 214.827KB
Recall 573 Report – 3/16/2022
RCLRPT-22E006-9487.PDF 215.007KB
Recall 573 Report – 07/17/2022
RCLRPT-22E006-1024.PDF 243.461KB
Recall 573 Report – 10/29/2022
RCLRPT-22E006-1397.PDF 215.007KB
Recall 573 Report – 7/17/2022
RCLRPT-22E006-8010.PDF 215.009KB
Recall 573 Report – February 13, 2023
RCLRPT-22E006-4626.PDF 215.008KB
December 6, 2022 Subject: Missing CY2022 Recall Information (Delay in Notifying Owners – NHTSA ID#22E006)
RCONL-22E006-9052.pdf 601.996KB
Manufacturer Notices(to Dealers,etc) – February 15, 2022 FW: Acknowledgement letter for Recall Campaign Number: 22E006
RCMN-22E006-8534.pdf 907.961KB
Recall 573 Report – 7/31/2023
RCLRPT-22E006-9136.PDF 215.556KB
Manufacturer Notices(to Dealers,etc) – Nexx X.R2_Product-Recall-Notice
Latest Recalls Documents
https://www-odi.nhtsa.dot.gov/acms/cs/documentList.xhtml?docId=22E006&docType=RCL
- High Resistance ABS Shell With Micrometrically Adjustable Strap
- Meets or Exceeds FMVSS-218 and DOT Safety Standards
- Helmet Liner / Cheek Pads are Lightweight, Soft and Easily Removable and Washable
- Sleek and Lightweight Design Reduces Wind Noise
- Modular Flip-Up Function Anti-Scratch, Anti-Fog and Wide View Clear Visor
- ★Meets or Exceeds FMVSS-218, DOT, and ECE-2205 Safety Standards.
- ★High-quality ABS shell with multi-Density EPS Foam inner liner.
- ★Premium lining: moisture wicking, breathable.The adjustment belt works perfectly and is well made,One-touch buckle adjustment system.
- ★Weight: 1.9 Ib,Retro German Army helmets, both men and women can use
- ★ Helmet size: It can fit your head in all sizes. M:57-58cm/22.5-22.8in,L:59-60cm/23.2-23.6in,XL:61-62cm/24-24.4in
- Boasting a compact, aerodynamic DOT shell design with sharp and aggressive styling for impeccable impact protection to excel whether short-distance street performance or long-distance touring comfort.
- Multiple conscientiously designed ventilation panels effective in streamlining the cooling process to assist with freshening the rider's experience. Large lower vent shutters for ease of use with riding gloves.
- Trendsetting springs for precise functionality ensuring a superior wind and water sealant layer. Unique 3D molded shield designed to ensure a distortion-free view throughout the entire field of vision.
- Removable Breath Guard rerouting the rider’s breath to reduce shield fogging. Inserted Chin Curtain designed to reduce wind turbulence and noise. Quick-Release Chin Strap for effortless usage.
- Fully removable, washable, and replaceable microfiber inner material that absorbs sweat without compromising comfort or security.
- DURABLE ABS MATERIAL: High-quality ABS material that provides superior protection and durability, ensuring safety during your rides.
- DUAL VISOR SYTEM: Comes with clear outer visor and built-in sunshield,easy to remove and replace.
- CONVERTIBLE DESIGN: The helmet features a convertible design, enabling seamless transitions between full-face and open face configurations, providing flexibility for different riding conditions and personal preferences.
- DETACHABLE VISOR&CHIN GUARD: Equipped with a removable visor and chin guard, this helmet offers enhanced functionality. The detachable components allow for easy customization and maintenance, enhancing your riding experience.
- COMFORT AND STYLE: Combining safety with style, High density EPS more firmer that provide good shock absorption,removable and washable liner and pad.
- ◆Classic, super-slim, open-face design with retro paint and custom graphics.
- ◆Quick Release Buckle - for easily getting on and off and holding the helmet securely on your head.
- ◆Full face motorcycle helmet, meets or exceeds DOT safety standards to ensure quality and safety, perfect for street motorcycles like cruisers.
- ◆Lightweight polycarbonate/ABS shell construction with removable/Washable interior, padded wind collar drastically reduces wind and road noise
- ◆Wicks moisture and wears like the technical fabric it is.
- Great and Beautiful UV protective finished,Light weight extremely durable
- Well vented all purpose product for summer,winter riding Main and off-road riding
- Sleek modular design,Flip up modular helmets
- Helmet Size: Large(59-60 CM,23 - 23 1/2 Inch),Hat Size :7 3/8 - 7 1/2
- Pacakge Included: 1x Helmet,1xHelmet Bag
- LEGALITY: The half motorcycle helmets comply with U.S. safety regulations and DOT FMVSS NO.218 certified
- Fashion Mask: The included fashion mask is designed to provide excellent breathability, ensuring fresh airflow while keeping out dust and debris. It allows you to breathe easily and comfortably, enhancing your overall riding comfort.
- Breathable Construction: Say goodbye to sweaty rides! This motorcycle half helmet is equipped with excellent heat dissipation structure, allowing air to circulate efficiently and preventing heat buildup. Enjoy a cool and comfortable riding experience, even on hot days.
- Lightweight and Easy to Wear: Weighing in at a lightweight, this cool helmet is designed to reduce strain, making it easy to wear for extended periods. The fine design ensures a snug fit without compromising comfort, allowing you to focus on the road ahead.
- Beautiful and Durable: Crafted with attention to detail, this skull cap half helmet boasts a beautiful finish that adds a touch of elegance to your riding gear. The high-quality ABS materials used in its construction ensure durability, providing long-lasting protection and style for your motorcycle adventures.
- Helmet shown with optional tinted shield. (Ships with clear shield only)
- Lightweight construction with a strong, durable outer shell to provide maximum protection
- NutraFog II shield which is a ClickRelease shield for fast, easy and tool-free shield replacement
- Velocity Flow Ventilation system designed to provide optimal airflow for comfortable wear
- DOT approved. Meets the FMVSS 218 Standard
- 【DLPACKJ】DLPACKJ Novel & Stylish german motorcycle helmet Design
- 【EXTREME COMFORT】 Moisture wicking fabric keeps your head cooler and more comfortable. Custom formed interior, for a super comfortable fit
- 【QUICK RELEASE】padded chin strap with quick release plastic buckle make it simple to get the helmet on and off
- 【APPLICABLE OCCASIONS】 Skull cap helmet can be used by adult men and women. It is suitable for motorcycles, scooters, street cars, mopeds, Four-wheeled vehicle.
- 【AFTER-SALE SERVICE】If the helmet size is not suitable, we provide free replacement service. Before confirming that the helmet is suitable, try to keep the packaging intact so as not to affect the exchange, thank you for your understanding
Last update on 2024-06-11 / Affiliate links / Images from Amazon Product Advertising API
This product presentation was made with AAWP plugin.
SEOCONTENT-START
~ r, –·~~
HELMETS
FOR LIFE
Via Electronic Mail
December 6, 2022
Pedro Duarte
Nexxpro – Fabrica de Capacetes, S.A.
Zona Industrial Amoreira da Gandara, Lote No. I I
3780-024 Amoreira da Gandara, Portugal
Subject: Missing CY2022 Recall Information (Delay in Notifying Owners – NHTSA
ID#22E006)
Dear All,
We hereby explain why the owner notification letters were not, so far, issued for this
recall.
1. Our dealer of nowadays (“VL”) is not the same of 2019’s, and since we have
an Nexx North America (NNA) warehouse, we had to check to which dealer
the affected helmets were sent.
According to our analysis, it is now ce1iain that were not sent to VL, and most
probably to Rev’it. Due to this, we are facing the second issue.
11. Between 2019 and 2020, our representative at NNA (Nexx North America)
and Rev’it resign and the whole organization was modified.
According to information it seems that at the time it was a harsh process,
almost leading to NNA’s end,
Due to this we are now facing major issues to obtain any information from
NNA & Rev’it (mainly in what concerns helmets sent to USA before 2020).
m. It is planned now to, with VL’s assistance, make an approach to every dealer
(the ones of 2019) to find out where the affected helmets are and to whom
were sold.
To prevent this from happening in the future, and as described previously, since 2020 we
have a different company (VL) working with us, with a different approach, more
professional, and with a capable traceability system.
ne:xxpro
fabrica de capacetes. S.A.
Soded.’lde .Anofjm11 NIPCJVAT:505 376 113 Cnpital Soclal (615.385,00 R~Uto CJl.C CH Anlldia sob o n• 505 376 113.
. , d capacetes, SA.
neXXl)rO I fabric& . ~- “‘””ata \Lole N’ ,,
slJialdeAimrefawuolll’ a\
Zona lndU reifa da GAndara I Nladia-l>otlu9 1 3780-024MV) NIPC: 505376\1•3-~ ~,-, .. ~
A n.1o liqu~1o d&Sta doc\lmento dE 3780-024Amollira da Gindara I Analfia.Portugal
, NIPC: 505376113
Issued.’ [July} {2023}
**************************************************************************************************************
1
Pedro Duarte
De: Pedro Duarte
Enviado: 15 de fevereiro de 2022 14:41
Para: Eric Van Leeuwen
Cc: Hélder Loureiro; António Patrício
Assunto: FW: Acknowledgement letter for Recall Campaign Number: 22E006
Anexos: RCAK-22E006-9909.pdf; Nexx X.R2_Product-Recall-Notice.docx
Importância: Alta
Dear Eric,
First of all, I hope you are doing well.
As you surely know, we are proceeding with a recall campaign for model X.R2. Details in attachment.
To start up, I kindly ask you to please:
1. check the attached product recall notice and to fill in your contact details, and then return it to me;
2. Inform us if, with the serial number of the affected helmets, it will be feasible/possible to find the end consumer on an estimated 30 days period.
(I know that this one is a tricky question, but I need to be aware of the recall campaign process to evaluate if we’ll need additional support.)
Thanks.
Cumprimentos / Best regards,
Pedro Duarte
Diretor da Qualidade / Quality Manager
pedro.duarte@nexxpro.com
2
Nexxpro, S.A.
Zona Industrial Amoreira da Gândara, Lote Nº11
3780-024 Amoreira da Gândara
Portugal
Phone. +351 231 590 010 / +351 925 949 259
Fax. +351 231 596 861
Email. nexx@nexxpro.com
www.nexx-helmets.com
De: Lee, Choon (NHTSA) <choon.lee@dot.gov>
Enviada: 10 de fevereiro de 2022 14:46
Para: Pedro Duarte <pedro.duarte@nexxpro.com> Assunto: Acknowledgement letter for Recall Campaign Number: 22E006
Importância: Alta
Hello Mr. Duarte,
Please review the attached acknowledgement letter for recall 22E-006 and ensure it matches your information. It is scheduled to be posted to NHTSA.gov tomorrow
morning.
Thank you and stay safe,
Choon Lee
Safety Recall Specialist
U.S. Department of Transportation
National Highway Traffic Safety Administration
Office of Defects Investigation
1200 New Jersey Avenue SE., Washington, DC 20590
W46-430
Tel: 202-366-0388
**************************************************************************************************************
OMB Control No.: 2127-0004
Part 573 Safety Recall Report 22E-006
The information contained in this report was submitted pursuant to 49 CFR §573
Manufacturer Name : Nexxpro – Fabrica de Capacetes, S.A.
Submission Date : MAR 16, 2022
NHTSA Recall No. : 22E-006
Manufacturer Recall No. : NR
Manufacturer Information :
Manufacturer Name : Nexxpro – Fabrica de Capacetes, S.A.
Address : Zona Industrial Amoreira da Gandara
Lote 11 – Amoreira da Gandara –
Anadia Anadia 00 3780-024
Company phone : 231590010
Population :
Number of potentially involved : 12
Estimated percentage with defect : 67 %
Equipment Information :
Brand / Trade 1 : NEXX
Model : X.R2
Part No. : 01XR22312455100M
Size : M
Function : Safety
Descriptive Information : – On the 1st of march’19, it had been reported/detected a setup machine failure,
leading to 18 non-conforming products. Those parts were submitted to a rework
process.
– Due to lack of knowledge of worker and inexistence of a poka-yoke system, on
12 of the reworked parts it was used a different carbon layer (240g/m2) than
the specified one (200g/m2).
– Reports of deviations during inventory of raw material + traceability records +
lab test results lead us to the serial number of the affected parts:
– 2019-99655
– 2019-99662
– 2019-99658
– 2019-99673
– 2019-99514
– 2019-99517
– 2019-99602
– 2019-99600
– 2019-99533
– 2019-99691
– 2019-99692
– 2019-99598
Production Dates : MAR 01, 2019 – MAR 01, 2019
Part 573 Safety Recall Report 22E-006 Page 2
The information contained in this report was submitted pursuant to 49 CFR §573
Description of Defect :
Description of the Defect : During a Safety Compliance Testing for FMVSS No. 218 Motorcycle Helmets, 3
of the 4 tested samples failed on the penetration test.
FMVSS 1 : 218 – Motorcycle helmets
FMVSS 2 : NR
Description of the Safety Risk : In case of accident, safety of the motorcyclist is compromised (eventually
serious injury or death)
Description of the Cause : The cause for this noncompliance is related with the use (during a rework
process) of a different carbon layer (240g/m2) than the specified one (200g/
m2).
So, the problem is not related with the raw material itself.
Identification of Any Warning
that can Occur :
–
Involved Components :
Component Name : NR
Component Description : NR
Component Part Number : NR
Supplier Identification :
Component Manufacturer
Name : Nexxpro – Fábrica de Capacetes, S.A.
Address : Z.I. Amoreira da Gandara
Lote 11 Anadia Foreign States 3780-024
Country : Portugal
Chronology :
Once reported the failure detected during a Safety Compliance Testing for FMVSS No. 218 Motorcycle Helmets
(dated 10 Sep 2020), it were picked some parts (of the same batch and also from another batch – 02) and
submitted to testing, in an external lab. All of the tested parts were conforming.
Details of the samples submitted to testing:
Part 573 Safety Recall Report 22E-006 Page 3
The information contained in this report was submitted pursuant to 49 CFR §573
– Laboratory: Omega (Italy); testing date: 02 Oct 2020; Report Nexxpro XR2 DOT 06102020 – batch 01
– Laboratory: Omega (Italy); testing date: 02 Oct 2020; Report Nexxpro XR2 DOT 06102020-1 – batch 02
It was requested info (S/N) regarding the S/N of the tested samples that failed. With those S/N it was possible
to find out part’s history.
According part’s history records, those 12 parts were all submitted to a rework process and, in all of them, it
was the same worker who proceeded with the rework and, at least in 11 of the 12 parts, a different raw
material (carbon layer) than the specified one was used, and so we do consider as potential affected parts the
12 described.
Description of Remedy :
Description of Remedy Program : Defect/noncompliance remedy program: some of the remaining parts –
same batch – were submitted to testing, with satisfactory results.
Registration of the raw material used on each manufacturing order is now
done through the IT system, and if a different Raw Material is used, the IT
system automatically issues a red alert, and the batch of the produced
parts is blocked.
Manufacturer’s plan for reimbursement: replacement by new helmets.
How Remedy Component Differs
from Recalled Component :
In the remedy component it was used the correct raw material (carbon
layer with 200g/m2).
Identify How/When Recall Condition
was Corrected in Production :
Recall condition was corrected on November’20.
Since this date, registration of the raw material used on each
manufacturing order is now done through the IT system, and if a different
Raw Material is used, the IT system automatically issues a red alert, and
the batch of the produced parts is blocked.
Moreover, it were checked all production records since mar’19, and part’s
history of all the produced helmets, and it weren’t found any deviations
related with wrongly raw material use.
Recall Schedule :
Description of Recall Schedule : NR
Planned Dealer Notification Date : FEB 07, 2022 – MAR 18, 2022
Planned Owner Notification Date : MAR 23, 2022 – APR 02, 2022
Part 573 Safety Recall Report 22E-006 Page 4
The information contained in this report was submitted pursuant to 49 CFR §573
Purchaser Information :
The following manufacturers purchased this defective/noncompliant equipment for possible use or
installation in new motor vehicles or new items of motor vehicle equipment:
Name : NR
Address : NR
NR
Country : NR
Company Phone : NR
* NR – Not Reported
**************************************************************************************************************
OMB Control No.: 2127-0004
Part 573 Safety Recall Report 22E-006
The information contained in this report was submitted pursuant to 49 CFR §573
Manufacturer Name : Nexxpro – Fabrica de Capacetes, S.A.
Submission Date : JUL 31, 2023
NHTSA Recall No. : 22E-006
Manufacturer Recall No. : NR
Manufacturer Information :
Manufacturer Name : Nexxpro – Fabrica de Capacetes, S.A.
Address : Zona Industrial Amoreira da Gandara
Lote 11 – Amoreira da Gandara –
Anadia Anadia 00 3780-024
Company phone : 231590010
Population :
Number of potentially involved : 12
Estimated percentage with defect : 67 %
Part 573 Safety Recall Report 22E-006 Page 2
The information contained in this report was submitted pursuant to 49 CFR §573
Equipment Information :
Brand / Trade 1 : NEXX
Model : X.R2
Part No. : 01XR22312455100M
Size : M
Function : Safety
Descriptive Information : – On the 1st of march’19, it had been reported/detected a setup machine failure,
leading to 18 non-conforming products. Those parts were submitted to a rework
process.
– Due to lack of knowledge of worker and inexistence of a poka-yoke system, on
12 of the reworked parts it was used a different carbon layer (240g/m2) than
the specified one (200g/m2).
– Reports of deviations during inventory of raw material + traceability records +
lab test results lead us to the serial number of the affected parts:
– 2019-99655
– 2019-99662
– 2019-99658
– 2019-99673
– 2019-99514
– 2019-99517
– 2019-99602
– 2019-99600
– 2019-99533
– 2019-99691
– 2019-99692
– 2019-99598
Helmets with manufacturing date from January 2019 to May 2019
Production Dates : MAR 01, 2019 – MAR 01, 2019
Description of Defect :
Description of the Defect : During a Safety Compliance Testing for FMVSS No. 218 Motorcycle Helmets, 3
of the 4 tested samples failed on the penetration test.
FMVSS 1 : 218 – Motorcycle helmets
FMVSS 2 : NR
Description of the Safety Risk : In case of accident, safety of the motorcyclist is compromised (eventually
serious injury or death)
Description of the Cause : The cause for this noncompliance is related with the use (during a rework
process) of a different carbon layer (240g/m2) than the specified one (200g/
Part 573 Safety Recall Report 22E-006 Page 3
The information contained in this report was submitted pursuant to 49 CFR §573
m2).
So, the problem is not related with the raw material itself.
Identification of Any Warning
that can Occur :
–
Involved Components :
Component Name : NR
Component Description : NR
Component Part Number : NR
Supplier Identification :
Component Manufacturer
Name : Nexxpro – Fábrica de Capacetes, S.A.
Address : Z.I. Amoreira da Gandara
Lote 11 Anadia Foreign States 3780-024
Country : Portugal
Chronology :
Once reported the failure detected during a Safety Compliance Testing for FMVSS No. 218 Motorcycle Helmets
(dated 10 Sep 2020), it were picked some parts (of the same batch and also from another batch – 02) and
submitted to testing, in an external lab. All of the tested parts were conforming.
Details of the samples submitted to testing:
– Laboratory: Omega (Italy); testing date: 02 Oct 2020; Report Nexxpro XR2 DOT 06102020 – batch 01
– Laboratory: Omega (Italy); testing date: 02 Oct 2020; Report Nexxpro XR2 DOT 06102020-1 – batch 02
It was requested info (S/N) regarding the S/N of the tested samples that failed. With those S/N it was possible
to find out part’s history.
According part’s history records, those 12 parts were all submitted to a rework process and, in all of them, it
was the same worker who proceeded with the rework and, at least in 11 of the 12 parts, a different raw
material (carbon layer) than the specified one was used, and so we do consider as potential affected parts the
12 described.
Part 573 Safety Recall Report 22E-006 Page 4
The information contained in this report was submitted pursuant to 49 CFR §573
Description of Remedy :
Description of Remedy Program : Defect/noncompliance remedy program: some of the remaining parts –
same batch – were submitted to testing, with satisfactory results.
Registration of the raw material used on each manufacturing order is now
done through the IT system, and if a different Raw Material is used, the IT
system automatically issues a red alert, and the batch of the produced
parts is blocked.
Manufacturer’s plan for reimbursement: replacement by new helmets.
How Remedy Component Differs
from Recalled Component :
In the remedy component it was used the correct raw material (carbon
layer with 200g/m2).
Identify How/When Recall Condition
was Corrected in Production :
Recall condition was corrected on November’20.
Since this date, registration of the raw material used on each
manufacturing order is now done through the IT system, and if a different
Raw Material is used, the IT system automatically issues a red alert, and
the batch of the produced parts is blocked.
Moreover, it were checked all production records since mar’19, and part’s
history of all the produced helmets, and it weren’t found any deviations
related with wrongly raw material use.
Recall Schedule :
Description of Recall Schedule : NR
Planned Dealer Notification Date : FEB 07, 2022 – MAR 18, 2022
Planned Owner Notification Date : JAN 01, 2023 – JUL 31, 2023
Purchaser Information :
The following manufacturers purchased this defective/noncompliant equipment for possible use or
installation in new motor vehicles or new items of motor vehicle equipment:
Part 573 Safety Recall Report 22E-006 Page 5
The information contained in this report was submitted pursuant to 49 CFR §573
Name : NR
Address : NR
NR
Country : NR
Company Phone : NR
* NR – Not Reported
**************************************************************************************************************
OMB Control No.: 2127-0004
Part 573 Safety Recall Report 22E-006
The information contained in this report was submitted pursuant to 49 CFR §573
Manufacturer Name : Nexxpro – Fabrica de Capacetes, S.A.
Submission Date : JUL 17, 2022
NHTSA Recall No. : 22E-006
Manufacturer Recall No. : NR
Manufacturer Information :
Manufacturer Name : Nexxpro – Fabrica de Capacetes, S.A.
Address : Zona Industrial Amoreira da Gandara
Lote 11 – Amoreira da Gandara –
Anadia Anadia 00 3780-024
Company phone : 231590010
Population :
Number of potentially involved : 12
Estimated percentage with defect : 67 %
Equipment Information :
Brand / Trade 1 : NEXX
Model : X.R2
Part No. : 01XR22312455100M
Size : M
Function : Safety
Descriptive Information : – On the 1st of march’19, it had been reported/detected a setup machine failure,
leading to 18 non-conforming products. Those parts were submitted to a rework
process.
– Due to lack of knowledge of worker and inexistence of a poka-yoke system, on
12 of the reworked parts it was used a different carbon layer (240g/m2) than
the specified one (200g/m2).
– Reports of deviations during inventory of raw material + traceability records +
lab test results lead us to the serial number of the affected parts:
– 2019-99655
– 2019-99662
– 2019-99658
– 2019-99673
– 2019-99514
– 2019-99517
– 2019-99602
– 2019-99600
– 2019-99533
– 2019-99691
– 2019-99692
– 2019-99598
Production Dates : MAR 01, 2019 – MAR 01, 2019
Part 573 Safety Recall Report 22E-006 Page 2
The information contained in this report was submitted pursuant to 49 CFR §573
Description of Defect :
Description of the Defect : During a Safety Compliance Testing for FMVSS No. 218 Motorcycle Helmets, 3
of the 4 tested samples failed on the penetration test.
FMVSS 1 : 218 – Motorcycle helmets
FMVSS 2 : NR
Description of the Safety Risk : In case of accident, safety of the motorcyclist is compromised (eventually
serious injury or death)
Description of the Cause : The cause for this noncompliance is related with the use (during a rework
process) of a different carbon layer (240g/m2) than the specified one (200g/
m2).
So, the problem is not related with the raw material itself.
Identification of Any Warning
that can Occur :
–
Involved Components :
Component Name : NR
Component Description : NR
Component Part Number : NR
Supplier Identification :
Component Manufacturer
Name : Nexxpro – Fábrica de Capacetes, S.A.
Address : Z.I. Amoreira da Gandara
Lote 11 Anadia Foreign States 3780-024
Country : Portugal
Chronology :
Once reported the failure detected during a Safety Compliance Testing for FMVSS No. 218 Motorcycle Helmets
(dated 10 Sep 2020), it were picked some parts (of the same batch and also from another batch – 02) and
submitted to testing, in an external lab. All of the tested parts were conforming.
Details of the samples submitted to testing:
Part 573 Safety Recall Report 22E-006 Page 3
The information contained in this report was submitted pursuant to 49 CFR §573
– Laboratory: Omega (Italy); testing date: 02 Oct 2020; Report Nexxpro XR2 DOT 06102020 – batch 01
– Laboratory: Omega (Italy); testing date: 02 Oct 2020; Report Nexxpro XR2 DOT 06102020-1 – batch 02
It was requested info (S/N) regarding the S/N of the tested samples that failed. With those S/N it was possible
to find out part’s history.
According part’s history records, those 12 parts were all submitted to a rework process and, in all of them, it
was the same worker who proceeded with the rework and, at least in 11 of the 12 parts, a different raw
material (carbon layer) than the specified one was used, and so we do consider as potential affected parts the
12 described.
Description of Remedy :
Description of Remedy Program : Defect/noncompliance remedy program: some of the remaining parts –
same batch – were submitted to testing, with satisfactory results.
Registration of the raw material used on each manufacturing order is now
done through the IT system, and if a different Raw Material is used, the IT
system automatically issues a red alert, and the batch of the produced
parts is blocked.
Manufacturer’s plan for reimbursement: replacement by new helmets.
How Remedy Component Differs
from Recalled Component :
In the remedy component it was used the correct raw material (carbon
layer with 200g/m2).
Identify How/When Recall Condition
was Corrected in Production :
Recall condition was corrected on November’20.
Since this date, registration of the raw material used on each
manufacturing order is now done through the IT system, and if a different
Raw Material is used, the IT system automatically issues a red alert, and
the batch of the produced parts is blocked.
Moreover, it were checked all production records since mar’19, and part’s
history of all the produced helmets, and it weren’t found any deviations
related with wrongly raw material use.
Recall Schedule :
Description of Recall Schedule : NR
Planned Dealer Notification Date : FEB 07, 2022 – MAR 18, 2022
Planned Owner Notification Date : MAR 23, 2022 – SEP 23, 2022
Part 573 Safety Recall Report 22E-006 Page 4
The information contained in this report was submitted pursuant to 49 CFR §573
Purchaser Information :
The following manufacturers purchased this defective/noncompliant equipment for possible use or
installation in new motor vehicles or new items of motor vehicle equipment:
Name : NR
Address : NR
NR
Country : NR
Company Phone : NR
* NR – Not Reported
**************************************************************************************************************
OMB Control No.: 2127-0004
Part 573 Safety Recall Report 22E-006
The information contained in this report was submitted pursuant to 49 CFR §573
Manufacturer Name : Nexxpro – Fabrica de Capacetes, S.A.
Submission Date : FEB 03, 2022
NHTSA Recall No. : 22E-006
Manufacturer Recall No. : NR
Manufacturer Information :
Manufacturer Name : Nexxpro – Fabrica de Capacetes, S.A.
Address : Zona Industrial Amoreira da Gandara
Lote 11 – Amoreira da Gandara –
Anadia Anadia 00 3780-024
Company phone : 231590010
Population :
Number of potentially involved : 12
Estimated percentage with defect : 67 %
Equipment Information :
Brand / Trade 1 : NEXX
Model : X.R2
Part No. : 01XR22312455100M
Size : M
Function : Safety
Descriptive Information : – On the 1st of march’19, it had been reported/detected a setup machine failure,
leading to 18 non-conforming products. Those parts were submitted to a rework
process.
– Due to lack of knowledge of worker and inexistence of a poka-yoke system, on
12 of the reworked parts it was used a different carbon layer (240g/m2) than
the specified one (200g/m2).
– Reports of deviations during inventory of raw material + traceability records +
lab test results lead us to the serial number of the affected parts:
– 2019-99655
– 2019-99662
– 2019-99658
– 2019-99673
– 2019-99514
– 2019-99517
– 2019-99602
– 2019-99600
– 2019-99533
– 2019-99691
– 2019-99692
– 2019-99598
Production Dates : MAR 01, 2019 – MAR 01, 2019
Part 573 Safety Recall Report 22E-006 Page 2
The information contained in this report was submitted pursuant to 49 CFR §573
Description of Defect :
Description of the Defect : During a Safety Compliance Testing for FMVSS No. 218 Motorcycle Helmets, 3
of the 4 tested samples failed on the penetration test.
FMVSS 1 : 218 – Motorcycle helmets
FMVSS 2 : NR
Description of the Safety Risk : In case of accident, safety of the motorcyclist is compromised.
Description of the Cause : The cause for this noncompliance is related with the use (during a rework
process) of a different carbon layer (240g/m2) than the specified one (200g/
m2).
So, the problem is not related with the raw material itself.
Identification of Any Warning
that can Occur :
–
Involved Components :
Component Name : NR
Component Description : NR
Component Part Number : NR
Supplier Identification :
Component Manufacturer
Name : Nexxpro – Fábrica de Capacetes, S.A.
Address : Z.I. Amoreira da Gandara
Lote 11 Anadia Foreign States 3780-024
Country : Portugal
Chronology :
Once reported the failure detected during a Safety Compliance Testing for FMVSS No. 218 Motorcycle Helmets,
it were picked some parts (of the same batch) and submitted to testing, in an external lab. All of the tested parts
were conforming.
It was requested info (S/N) regarding the S/N of the tested samples that failed. With those S/N it was possible
to find out part’s history.
Part 573 Safety Recall Report 22E-006 Page 3
The information contained in this report was submitted pursuant to 49 CFR §573
According part’s history records, those 12 parts were all submitted to a rework process and, in all of them, it
was the same worker who proceeded with the rework and, at least in 11 of the 12 parts, a different raw
material (carbon layer) than the specified one was used, and so we do consider as potential affected parts the
12 described.
Description of Remedy :
Description of Remedy Program : Defect/noncompliance remedy program: some of the remaining parts –
same batch – were submitted to testing, with satisfactory results.
Registration of the raw material used on each manufacturing order is now
done through the IT system, and if a different Raw Material is used, the IT
system automatically issues a red alert, and the batch of the produced
parts is blocked.
Manufacturer’s plan for reimbursement: replacement by new helmets.
How Remedy Component Differs
from Recalled Component :
In the remedy component it was used the correct raw material (carbon
layer with 200g/m2).
Identify How/When Recall Condition
was Corrected in Production :
Recall condition was corrected on November’20.
Since this date, registration of the raw material used on each
manufacturing order is now done through the IT system, and if a different
Raw Material is used, the IT system automatically issues a red alert, and
the batch of the produced parts is blocked.
Moreover, it were checked all production records since mar’19, and part’s
history of all the produced helmets, and it weren’t found any deviations
related with wrongly raw material use.
Recall Schedule :
Description of Recall Schedule : NR
Planned Dealer Notification Date : FEB 07, 2022 – FEB 14, 2022
Planned Owner Notification Date : FEB 15, 2022 – MAR 22, 2022
Purchaser Information :
The following manufacturers purchased this defective/noncompliant equipment for possible use or
installation in new motor vehicles or new items of motor vehicle equipment:
Part 573 Safety Recall Report 22E-006 Page 4
The information contained in this report was submitted pursuant to 49 CFR §573
Name : NR
Address : NR
NR
Country : NR
Company Phone : NR
* NR – Not Reported
**************************************************************************************************************
OMB Control No.: 2127-0004
Part 573 Safety Recall Report 22E-006
The information contained in this report was submitted pursuant to 49 CFR §573
Manufacturer Name : Nexxpro – Fabrica de Capacetes, S.A.
Submission Date : FEB 13, 2023
NHTSA Recall No. : 22E-006
Manufacturer Recall No. : NR
Manufacturer Information :
Manufacturer Name : Nexxpro – Fabrica de Capacetes, S.A.
Address : Zona Industrial Amoreira da Gandara
Lote 11 – Amoreira da Gandara –
Anadia Anadia 00 3780-024
Company phone : 231590010
Population :
Number of potentially involved : 12
Estimated percentage with defect : 67 %
Equipment Information :
Brand / Trade 1 : NEXX
Model : X.R2
Part No. : 01XR22312455100M
Size : M
Function : Safety
Descriptive Information : – On the 1st of march’19, it had been reported/detected a setup machine failure,
leading to 18 non-conforming products. Those parts were submitted to a rework
process.
– Due to lack of knowledge of worker and inexistence of a poka-yoke system, on
12 of the reworked parts it was used a different carbon layer (240g/m2) than
the specified one (200g/m2).
– Reports of deviations during inventory of raw material + traceability records +
lab test results lead us to the serial number of the affected parts:
– 2019-99655
– 2019-99662
– 2019-99658
– 2019-99673
– 2019-99514
– 2019-99517
– 2019-99602
– 2019-99600
– 2019-99533
– 2019-99691
– 2019-99692
– 2019-99598
Production Dates : MAR 01, 2019 – MAR 01, 2019
Part 573 Safety Recall Report 22E-006 Page 2
The information contained in this report was submitted pursuant to 49 CFR §573
Description of Defect :
Description of the Defect : During a Safety Compliance Testing for FMVSS No. 218 Motorcycle Helmets, 3
of the 4 tested samples failed on the penetration test.
FMVSS 1 : 218 – Motorcycle helmets
FMVSS 2 : NR
Description of the Safety Risk : In case of accident, safety of the motorcyclist is compromised (eventually
serious injury or death)
Description of the Cause : The cause for this noncompliance is related with the use (during a rework
process) of a different carbon layer (240g/m2) than the specified one (200g/
m2).
So, the problem is not related with the raw material itself.
Identification of Any Warning
that can Occur :
–
Involved Components :
Component Name : NR
Component Description : NR
Component Part Number : NR
Supplier Identification :
Component Manufacturer
Name : Nexxpro – Fábrica de Capacetes, S.A.
Address : Z.I. Amoreira da Gandara
Lote 11 Anadia Foreign States 3780-024
Country : Portugal
Chronology :
Once reported the failure detected during a Safety Compliance Testing for FMVSS No. 218 Motorcycle Helmets
(dated 10 Sep 2020), it were picked some parts (of the same batch and also from another batch – 02) and
submitted to testing, in an external lab. All of the tested parts were conforming.
Details of the samples submitted to testing:
Part 573 Safety Recall Report 22E-006 Page 3
The information contained in this report was submitted pursuant to 49 CFR §573
– Laboratory: Omega (Italy); testing date: 02 Oct 2020; Report Nexxpro XR2 DOT 06102020 – batch 01
– Laboratory: Omega (Italy); testing date: 02 Oct 2020; Report Nexxpro XR2 DOT 06102020-1 – batch 02
It was requested info (S/N) regarding the S/N of the tested samples that failed. With those S/N it was possible
to find out part’s history.
According part’s history records, those 12 parts were all submitted to a rework process and, in all of them, it
was the same worker who proceeded with the rework and, at least in 11 of the 12 parts, a different raw
material (carbon layer) than the specified one was used, and so we do consider as potential affected parts the
12 described.
Description of Remedy :
Description of Remedy Program : Defect/noncompliance remedy program: some of the remaining parts –
same batch – were submitted to testing, with satisfactory results.
Registration of the raw material used on each manufacturing order is now
done through the IT system, and if a different Raw Material is used, the IT
system automatically issues a red alert, and the batch of the produced
parts is blocked.
Manufacturer’s plan for reimbursement: replacement by new helmets.
How Remedy Component Differs
from Recalled Component :
In the remedy component it was used the correct raw material (carbon
layer with 200g/m2).
Identify How/When Recall Condition
was Corrected in Production :
Recall condition was corrected on November’20.
Since this date, registration of the raw material used on each
manufacturing order is now done through the IT system, and if a different
Raw Material is used, the IT system automatically issues a red alert, and
the batch of the produced parts is blocked.
Moreover, it were checked all production records since mar’19, and part’s
history of all the produced helmets, and it weren’t found any deviations
related with wrongly raw material use.
Recall Schedule :
Description of Recall Schedule : NR
Planned Dealer Notification Date : FEB 07, 2022 – MAR 18, 2022
Planned Owner Notification Date : JAN 01, 2023 – JUL 31, 2023
Part 573 Safety Recall Report 22E-006 Page 4
The information contained in this report was submitted pursuant to 49 CFR §573
Purchaser Information :
The following manufacturers purchased this defective/noncompliant equipment for possible use or
installation in new motor vehicles or new items of motor vehicle equipment:
Name : NR
Address : NR
NR
Country : NR
Company Phone : NR
* NR – Not Reported
**************************************************************************************************************
OMB Control No.: 2127-0004
Part 573 Safety Recall Report 22E-006
The information contained in this report was submitted pursuant to 49 CFR §573
Manufacturer Name : Nexxpro – Fabrica de Capacetes, S.A.
Submission Date : OCT 29, 2022
NHTSA Recall No. : 22E-006
Manufacturer Recall No. : NR
Manufacturer Information :
Manufacturer Name : Nexxpro – Fabrica de Capacetes, S.A.
Address : Zona Industrial Amoreira da Gandara
Lote 11 – Amoreira da Gandara –
Anadia Anadia 00 3780-024
Company phone : 231590010
Population :
Number of potentially involved : 12
Estimated percentage with defect : 67 %
Equipment Information :
Brand / Trade 1 : NEXX
Model : X.R2
Part No. : 01XR22312455100M
Size : M
Function : Safety
Descriptive Information : – On the 1st of march’19, it had been reported/detected a setup machine failure,
leading to 18 non-conforming products. Those parts were submitted to a rework
process.
– Due to lack of knowledge of worker and inexistence of a poka-yoke system, on
12 of the reworked parts it was used a different carbon layer (240g/m2) than
the specified one (200g/m2).
– Reports of deviations during inventory of raw material + traceability records +
lab test results lead us to the serial number of the affected parts:
– 2019-99655
– 2019-99662
– 2019-99658
– 2019-99673
– 2019-99514
– 2019-99517
– 2019-99602
– 2019-99600
– 2019-99533
– 2019-99691
– 2019-99692
– 2019-99598
Production Dates : MAR 01, 2019 – MAR 01, 2019
Part 573 Safety Recall Report 22E-006 Page 2
The information contained in this report was submitted pursuant to 49 CFR §573
Description of Defect :
Description of the Defect : During a Safety Compliance Testing for FMVSS No. 218 Motorcycle Helmets, 3
of the 4 tested samples failed on the penetration test.
FMVSS 1 : 218 – Motorcycle helmets
FMVSS 2 : NR
Description of the Safety Risk : In case of accident, safety of the motorcyclist is compromised (eventually
serious injury or death)
Description of the Cause : The cause for this noncompliance is related with the use (during a rework
process) of a different carbon layer (240g/m2) than the specified one (200g/
m2).
So, the problem is not related with the raw material itself.
Identification of Any Warning
that can Occur :
–
Involved Components :
Component Name : NR
Component Description : NR
Component Part Number : NR
Supplier Identification :
Component Manufacturer
Name : Nexxpro – Fábrica de Capacetes, S.A.
Address : Z.I. Amoreira da Gandara
Lote 11 Anadia Foreign States 3780-024
Country : Portugal
Chronology :
Once reported the failure detected during a Safety Compliance Testing for FMVSS No. 218 Motorcycle Helmets
(dated 10 Sep 2020), it were picked some parts (of the same batch and also from another batch – 02) and
submitted to testing, in an external lab. All of the tested parts were conforming.
Details of the samples submitted to testing:
Part 573 Safety Recall Report 22E-006 Page 3
The information contained in this report was submitted pursuant to 49 CFR §573
– Laboratory: Omega (Italy); testing date: 02 Oct 2020; Report Nexxpro XR2 DOT 06102020 – batch 01
– Laboratory: Omega (Italy); testing date: 02 Oct 2020; Report Nexxpro XR2 DOT 06102020-1 – batch 02
It was requested info (S/N) regarding the S/N of the tested samples that failed. With those S/N it was possible
to find out part’s history.
According part’s history records, those 12 parts were all submitted to a rework process and, in all of them, it
was the same worker who proceeded with the rework and, at least in 11 of the 12 parts, a different raw
material (carbon layer) than the specified one was used, and so we do consider as potential affected parts the
12 described.
Description of Remedy :
Description of Remedy Program : Defect/noncompliance remedy program: some of the remaining parts –
same batch – were submitted to testing, with satisfactory results.
Registration of the raw material used on each manufacturing order is now
done through the IT system, and if a different Raw Material is used, the IT
system automatically issues a red alert, and the batch of the produced
parts is blocked.
Manufacturer’s plan for reimbursement: replacement by new helmets.
How Remedy Component Differs
from Recalled Component :
In the remedy component it was used the correct raw material (carbon
layer with 200g/m2).
Identify How/When Recall Condition
was Corrected in Production :
Recall condition was corrected on November’20.
Since this date, registration of the raw material used on each
manufacturing order is now done through the IT system, and if a different
Raw Material is used, the IT system automatically issues a red alert, and
the batch of the produced parts is blocked.
Moreover, it were checked all production records since mar’19, and part’s
history of all the produced helmets, and it weren’t found any deviations
related with wrongly raw material use.
Recall Schedule :
Description of Recall Schedule : NR
Planned Dealer Notification Date : FEB 07, 2022 – MAR 18, 2022
Planned Owner Notification Date : MAR 23, 2022 – DEC 31, 2022
Part 573 Safety Recall Report 22E-006 Page 4
The information contained in this report was submitted pursuant to 49 CFR §573
Purchaser Information :
The following manufacturers purchased this defective/noncompliant equipment for possible use or
installation in new motor vehicles or new items of motor vehicle equipment:
Name : NR
Address : NR
NR
Country : NR
Company Phone : NR
* NR – Not Reported
**************************************************************************************************************
OMB Control No.: 2127-0004
Part 573 Safety Recall Report 22E-006
The information contained in this report was submitted pursuant to 49 CFR §573
Manufacturer Name : Nexxpro – Fabrica de Capacetes, S.A.
Submission Date : JUL 17, 2022
NHTSA Recall No. : 22E-006
Manufacturer Recall No. : NR
Manufacturer Information :
Manufacturer Name : Nexxpro – Fabrica de Capacetes, S.A.
Address : Zona Industrial Amoreira da Gandara
Lote 11 – Amoreira da Gandara –
Anadia Anadia 00 3780-024
Company phone : 231590010
Population :
Number of potentially involved : 12
Estimated percentage with defect : 67 %
Equipment Information :
Brand / Trade 1 : NEXX
Model : X.R2
Part No. : 01XR22312455100M
Size : M
Function : Safety
Descriptive Information : – On the 1st of march’19, it had been reported/detected a setup machine failure,
leading to 18 non-conforming products. Those parts were submitted to a rework
process.
– Due to lack of knowledge of worker and inexistence of a poka-yoke system, on
12 of the reworked parts it was used a different carbon layer (240g/m2) than
the specified one (200g/m2).
– Reports of deviations during inventory of raw material + traceability records +
lab test results lead us to the serial number of the affected parts:
– 2019-99655
– 2019-99662
– 2019-99658
– 2019-99673
– 2019-99514
– 2019-99517
– 2019-99602
– 2019-99600
– 2019-99533
– 2019-99691
– 2019-99692
– 2019-99598
Production Dates : MAR 01, 2019 – MAR 01, 2019
Part 573 Safety Recall Report 22E-006 Page 2
The information contained in this report was submitted pursuant to 49 CFR §573
Description of Defect :
Description of the Defect : During a Safety Compliance Testing for FMVSS No. 218 Motorcycle Helmets, 3
of the 4 tested samples failed on the penetration test.
FMVSS 1 : 218 – Motorcycle helmets
FMVSS 2 : NR
Description of the Safety Risk : In case of accident, safety of the motorcyclist is compromised (eventually
serious injury or death)
Description of the Cause : The cause for this noncompliance is related with the use (during a rework
process) of a different carbon layer (240g/m2) than the specified one (200g/
m2).
So, the problem is not related with the raw material itself.
Identification of Any Warning
that can Occur :
–
Involved Components :
Component Name : NR
Component Description : NR
Component Part Number : NR
Supplier Identification :
Component Manufacturer
Name : Nexxpro – Fábrica de Capacetes, S.A.
Address : Z.I. Amoreira da Gandara
Lote 11 Anadia Foreign States 3780-024
Country : Portugal
Chronology :
Once reported the failure detected during a Safety Compliance Testing for FMVSS No. 218 Motorcycle Helmets
(dated 10 Sep 2020), it were picked some parts (of the same batch and also from another batch – 02) and
submitted to testing, in an external lab. All of the tested parts were conforming.
Details of the samples submitted to testing:
Part 573 Safety Recall Report 22E-006 Page 3
The information contained in this report was submitted pursuant to 49 CFR §573
– Laboratory: Omega (Italy); testing date: 02 Oct 2020; Report Nexxpro XR2 DOT 06102020 – batch 01
– Laboratory: Omega (Italy); testing date: 02 Oct 2020; Report Nexxpro XR2 DOT 06102020-1 – batch 02
It was requested info (S/N) regarding the S/N of the tested samples that failed. With those S/N it was possible
to find out part’s history.
According part’s history records, those 12 parts were all submitted to a rework process and, in all of them, it
was the same worker who proceeded with the rework and, at least in 11 of the 12 parts, a different raw
material (carbon layer) than the specified one was used, and so we do consider as potential affected parts the
12 described.
Description of Remedy :
Description of Remedy Program : Defect/noncompliance remedy program: some of the remaining parts –
same batch – were submitted to testing, with satisfactory results.
Registration of the raw material used on each manufacturing order is now
done through the IT system, and if a different Raw Material is used, the IT
system automatically issues a red alert, and the batch of the produced
parts is blocked.
Manufacturer’s plan for reimbursement: replacement by new helmets.
How Remedy Component Differs
from Recalled Component :
In the remedy component it was used the correct raw material (carbon
layer with 200g/m2).
Identify How/When Recall Condition
was Corrected in Production :
Recall condition was corrected on November’20.
Since this date, registration of the raw material used on each
manufacturing order is now done through the IT system, and if a different
Raw Material is used, the IT system automatically issues a red alert, and
the batch of the produced parts is blocked.
Moreover, it were checked all production records since mar’19, and part’s
history of all the produced helmets, and it weren’t found any deviations
related with wrongly raw material use.
Recall Schedule :
Description of Recall Schedule : NR
Planned Dealer Notification Date : FEB 07, 2022 – MAR 18, 2022
Planned Owner Notification Date : MAR 23, 2022 – SEP 23, 2022
Part 573 Safety Recall Report 22E-006 Page 4
The information contained in this report was submitted pursuant to 49 CFR §573
Purchaser Information :
The following manufacturers purchased this defective/noncompliant equipment for possible use or
installation in new motor vehicles or new items of motor vehicle equipment:
Name : NR
Address : NR
NR
Country : NR
Company Phone : NR
* NR – Not Reported
SEOCONTENT-END