“This site contains affiliate links for which OEMDTC may be compensated” |
June 11, 2024 NHTSA CAMPAIGN NUMBER: 24V427000
Incorrect Circuit Breaker May Cause Fire
Wiring that overheats increases the risk of a fire.
NHTSA Campaign Number: 24V427
Manufacturer Thor Motor Coach
Components ELECTRICAL SYSTEM
Potential Number of Units Affected 11
Summary
Thor Motor Coach (TMC) is recalling certain 2025 Thor Tranquility and Sanctuary motorhomes. A 50 AMP circuit breaker was incorrectly installed when a 20 AMP breaker is required, which can result in overheated wiring.
Remedy
Dealers will install a 20 AMP circuit breaker, free of charge. Owner notification letters are expected to be mailed August 6, 2024. Owners may contact TMC customer service at 1-877-500-1020. TMC’s number for this recall is RC000305.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.
Chronology :
5/21/24 – During an online production audit, the use of an incorrect breaker was discovered. An investigation into the incorrect breaker was commenced.
6/4/24 – TMC’s Safety Committee meeting occurred and all agreed to file a recall. No warranty claims or customer complaints have been received.
2 Affected Products
Vehicles
MAKE | MODEL | YEAR |
THOR MOTOR COACH | SANCTUARY | 2025 |
THOR MOTOR COACH | TRANQUILITY | 2025 |
2 Associated Documents
Recall Acknowledgement
RCAK-24V427-1024.pdf 645.949KB
Defect Recall 573 Report
RCLRPT-24V427-4555.PDF 215.04KB
Latest Recalls Documents
https://www-odi.nhtsa.dot.gov/acms/cs/documentList.xhtml?docId=24V427&docType=RCL
- Protect your system: using as circuit breaker and battery Disconnect, allows to charge or maintain the battery without having to disconnect all the wires! protect excessive current between battery or electrical from damage.
- Solid breaker: new design with waterproof resistant housing and solid build. Fuse breaker Holders have Pass professional electrical performance test and aging test, the switch button is on/off smoothly, reliable quality.
- Manual reset: Unique on/ off reset push button, mounted on panel or firewall, can used as a kill switch. No need to buy more replacing fuses.
- Application: used in auxiliary and accessory circuits for fit to Boat Marine RV Yacht Battery Trailer Bus Truck ATV Winches applications. Also used in battery charges and DC sound amplifier system.
- Max current 60A; Voltage DC 24V. Tubular electrical wire end cable lugs is included.
- CBC-B Series, Type I, Heavy Duty Circuit Breakers are ideal for many heavy-duty and truck applications
- Automatic Reset - resets automatically but will continue to trip (cycle on and off) until fault is corrected
- 20 Amp, 14 DC
- 10-32 stud-terminals, plastic base, metal housing, and crosswise metal mounting bracket
- Meets SAE J553 standards; sold individually
- Protect your system: using as circuit breaker and battery Disconnect, allows to charge or maintain the battery without having to disconnect all the wires! protect excessive current between battery or electrical from damage.
- Solid breaker: new design with waterproof resistant housing and solid build. Fuse breaker Holders have Pass professional electrical performance test and aging test, the switch button is on/off smoothly, reliable quality.
- Manual reset: Unique on/ off reset push button, mounted on panel or firewall, can used as a kill switch. No need to buy more replacing fuses.
- Application: used in auxiliary and accessory circuits for fit to Boat Marine RV Yacht Battery Trailer Bus Truck ATV Winches applications. Also used in battery charges and DC sound amplifier system.
- Use the waterproof cover to better prevent rust from metal parts. Max current 60A; Voltage DC 24V.
- Specification: 100 amp circuit breaker; Voltage: 12V - 48V DC; Waterproof; Ignition Protected: S.A.E. J1625, J1171, UL1500
- Reusable: This 100A breaker is designed with a push button and reset bar, which makes the 12 volt circuit breaker more than a dc breaker, it can also be used as a kill switch.
- Function: The 100 amp breaker can protect your vehicles or marine boats from electrical damage, prevents excessive current, and stops power surges from damaging Amps.
- Appliaction: This dc circuit breaker is typically used in truck, buses, RVs, Caravan, Winch, Tractor and ATV. In addition, the automotive circuit breaker can also be used as marine circuit breaker due to its waterproof function, for boat, yacht, etc.
- What you get: 2 x Waterproof Circuit Breaker, 4 x Wire Lugs, 8 x Washers, 1 Year Warranty, 24h Fast Respond Customer Service.
- · Function: This circuit breaker can protect the amplifier from being damaged by the over-load current or voltage. Meanwhile, the power supply can also be protected to avoid battery crack and explosion caused by short circuit.
- · Specification: Voltage 12-48V DC, compatible with all 12V/24V Systems. Ambient temperature: -32 ° c to 82 ° c (-25 ° f to 180 ° f) ,Accessories added wire lugs and Copper washer.
- · Manual Reset Circuit Breaker, Use in place of an inline fuse holder, the unique push button reset can also be used as a Kill Switch.
- · Protects your trolling motor from electrical damage, prevents excessive current and stops power surges from damaging Amps.
- · Application: Suitable for car audio/video system, boat, trucks, buses, RV's, ATV winches, marine and DC sound amplifier system overload protection.
- ✅【Powerful Marine Circuit Protection】 150 amp circuit breaker protects your trolling motor from electrical damage, prevents excessive current and stops power surges from damaging Amps. Ignition Protected, meets safety standards including S.A.E. J1625, J1171, and UL1500, ensuring ignition protection. This marine circuit breaker is designed for safe and reliable operation.
- ✅【Versatile Applications】 This 12V circuit breaker is suitable for various applications, including marine, automotive, and DC circuits. Perfect for use in auxiliary and accessory circuits for boats, marine vessels, RVs, yachts, batteries, trailers, buses, trucks, ATVs, winches, and more.
- ✅【Easy Manual Reset and Kill Switch】Unique on/off reset push button allows for easy manual reset, eliminating the need for frequent fuse replacements. Doubles as a convenient kill switch for added functionality.
- ✅【Solid and Waterproof Design】 Solid build with a new design and waterproof-resistant housing. Fuse breaker holders pass professional electrical performance and aging tests, ensuring a smooth on/off switch operation and reliable quality.
- ✅【Easy Installation with Rust Prevention】Effortless installation with surface mount capability. Mount on the panel or firewall with the included protective stud insulator. The waterproof cover prevents rust on metal parts, ensuring longevity.
- 7 Pack - 5A, 7.5A, 10A, 15A, 20A, 25A, 30A -- ATO / ATC Manual Reset (T3) Circuit Breakers
- UL-Rated 94V0 thermoplastic body with tin-plated copper alloy terminals
- 5.2mm wide blades, compatible with ATO/ATC type fuse blocks
- Automatic recovery functions and overcurrent protection
- Compliances: SAEJ553; SAEJ1171 (Ignition protected)
- Safe and practical to use: never worry about fuse burn-out with thermal automatic reset feature, power protected when circuit is overloaded/ shorting by this over-current circuit breaker
- Waterproof protective cover: the red protective cover avoid electrical shorts and corrosion, quality and waterproof, 10-32 stud bolt terminals, reliable plastic rustproof housing, can well protect the internal circuit breaker
- Wide applications: suitable for automotive, electromechanical equipment, vehicle, marine, off road and other vehicles, yachts and ships, truck applications, car engines electrical control etc, bring your life more convenience
- What you receive: you will receive 4 pieces of DC 12V - 24V automatic reset circuit breakers in this package, enough quantity to meet your various use and replacement, also nice to share with your friends and family who need them
- Functions: no worry about fuse burn out with thermal automatic reset feature, power protected when circuit is overloaded/ shorting by this over current circuit breaker
- 1, 5A/ 10A/ 15A/ 20A/ 25A/ 30A @ 14V dc - 6 Pack ATO/ ATC Automatic Reset (T1) Circuit Breakers
- 2, NOTE: The height (excluding terminals) of this breaker is 1.16" (29.5 mm), BUT the standard fuse usually is 0.48" (12.19 mm).
- 3, Materials: UL-Rated 94V0 thermoplastic body. Tin-plated Copper alloy terminals
- 4, Termination: 5.2mm wide blades compatible with ATO/ ATC type fuse blocks
- 5, Compliances: SAEJ553; SAEJ1171 ( Ignition protected)
- Reset Type:T1, Auto Reset,Voltage:14 Vdc,Rated Current:5A,10A,15A,20A,25A,30A
- Termination:0.32" (8.1mm) centerline spacing (Mini Type)
- Compliances: SAEJ553; SAEJ1171 (Ignition protected)
- UL-Rated 94V0 thermoplastic body. Tin-plated copper alloy terminals
- Package Include:5A,10A,15A,20A,25A,30A 6pcs Mixed/set
Last update on 2024-06-11 / Affiliate links / Images from Amazon Product Advertising API
This product presentation was made with AAWP plugin.
SEOCONTENT-START
OMB Control No.: 2127-0004
Part 573 Safety Recall Report 24V-427
The information contained in this report was submitted pursuant to 49 CFR §573
Manufacturer Name : Submission Date :
Thor Motor Coach JUN 10, 2024 NHTSA Recall No. : 24V-427 Manufacturer Recall No. : RC000305
Manufacturer Information :
Manufacturer Name : Thor Motor Coach Address : PO Box 1486
701 County Road 15 Elkhart IN 46515
Company phone : 877-500-1020
Population :
Number of potentially involved : 11 Estimated percentage with defect : 100 %
Vehicle Information : Vehicle 1 : 2025-2025 Thor Motor Coach Tranquility, Sanctuary Vehicle Type : LIGHT VEHICLES Body Style : VAN Power Train : DIESEL
Descriptive Information : An incorrect breaker was installed during production. A 50 amp breaker was installed on the power sofa circuit which was designed to use a 20 amp circuit breaker.
Production Dates : APR 04, 2024 – MAY 09, 2024 VIN Range 1 : Begin : w1x4nbvy8pp562307 End : w1x8nd6y0rp628184 ✔ Not sequential Description of Noncompliance :
tion of the
e :
A 50 amp breaker was installed instead of a 20 amp breaker FMVSS 1 : NR FMVSS 2 : NR
Description of the Safety Risk : The 10 gauge wire is under protected and can overheat which can lead to an increased risk of fire and personal injury.
Description of the Cause : Production installed the wrong size breaker. Identification of Any Warning
that can Occur : The 50 amp breaker in the main fuse panel for the power sofa will have “50” stamped into the lever.
Involved Components : Part 573 Safety Recall Report 24V-427 Page 2 Component Name 1 : 32V, 50 Amp, type 3, manual reset Component Description : Breaker
Component Part Number : 0548883 Supplier Identification : Component Manufacturer
Name : NR Address : NR
NR
Country : NR Chronology :
5/21/24 – During an online production audit, the use of an incorrect breaker was discovered. An investigation into the incorrect breaker was commenced. 6/4/24 – TMC’s Safety Committee meeting occurred and all agreed to file a recall. No warranty claims or customer complaints have been received. Description of Remedy :
Description of Remedy Program : A 50 amp breaker was installed on the power sofa circuit which was
designed to use a 20 amp circuit breaker. This circuit utilizes a 10 gauge wire. A 20 amp circuit breaker will be installed at no cost to the owner. Any reimbursement will follow the general reimbursement plan that is on file with NHTSA How Remedy Component Differs from Recalled Component :
Identify How/When Recall Condition was Corrected in Production : A 20 amp breaker is installed in the power sofa circuit location of the main fuse panel.
Upon completion of the audit, engineering verified the prints were correct, and notified production of the incorrect breaker. Production began installing the correct breaker. Recall Schedule :
Description of Recall Schedule : Thor Motor Coach has the utmost urgency in notifying owners about
recalls that affect their products. Letters will be sent out once all pertinent information has been gathered.
Planned Dealer Notification Date : AUG 06, 2024 – AUG 06, 2024
Planned Owner Notification Date : AUG 06, 2024 – AUG 06, 2024
The information contained in this report was submitted pursuant to 49 CFR §573 Part 573 Safety Recall Report 24V-427
Page 3
The information contained in this report was submitted pursuant to 49 CFR §573
* NR – Not Reported
**************************************************************************************************************
**************************************************************************************************************
SEOCONTENT-END