NHTSA ID Number: 10169768
Manufacturer Communication Number: SMB189
Summary
Service Manual Bulletin – Update to high voltage safety procedures, specifically Lockout/Tagout, de-energizing and re-energizing procedures for both battery electric and fuel cell buses.
19 Affected Products
Vehicles
MAKE | MODEL | YEAR |
NEW FLYER | XE35 | 2019-2020 |
NEW FLYER | XE40 | 2013-2020 |
NEW FLYER | XE60 | 2017-2020 |
NEW FLYER | XHE40 | 2018-2020 |
NEW FLYER | XHE60 | 2015, 2020 |
SMB-189
ISSUE DATE: Dec 20 2019
High Voltage Safety – Lockout / Tagout & De-Energizing & Energizing Procedure
This bulletin provides revised lockout / tagout and de-energizing and energizing procedures on your New Flyer vehicles in Three Parts.
Make this Service Bulletin available to service personnel to inform them of changed information.
SEOCONTENT-START
SMB-189 1 of 12
SERVICE MANUAL BULLETIN
This Service Manual Bulletin is prepared by the Publications Department of New Flyer Industries
Canada ULC. Refer to details below.
The New Flyer vehicles described in this manual may be protected by one or more
patents and design applications or registrations in the United States and Canada,
and in other countries. Refer to “Vehicle Patent Information” in this manual.
Copyright © 2019 New Flyer Industries Canada ULC
ISSUE DATE: Dec 20 2019
SMB-189
APPLICABILITY
VEHICLE LENGTH 30ft. 35ft. 40ft. 60ft. ALL
VEHICLE TYPE
Xcelsior® MiDi® Invero®
ALL
Low Floor High Floor
FUEL TYPE
Diesel Diesel/Electric CNG LNG
ALL
Fuel Cell Trolley/Electric Battery/Electric
SUBJECT High Voltage Safety – Lockout / Tagout & De-Energizing & Energizing
Procedure
SECTION TITLE Lockout / Tagout & De-Energizing & Energizing Procedure
DETAILS This bulletin provides revised lockout / tagout and de-energizing and
energizing procedures on your New Flyer vehicles in Three Parts.
Make this Service Bulletin available to service personnel to inform them
of changed information.
2 of 12 SMB-189
SERVICE MANUAL BULLETIN
SMB-189
The New Flyer vehicles described in this manual may be protected by one or more
patents and design applications or registrations in the United States and Canada,
and in other countries. Refer to “Vehicle Patent Information” in this manual.
Copyright © 2019 New Flyer Industries Canada ULC
PART ONE
1. Lockout / Tagout Procedure
for all Battery Electric
Vehicles
The following Lock Out / Tag Out procedure
should be followed when working on
or near the High Voltage components.
☞NOTE:
Use commercially available lock out equipment
and tags and be sure to follow any
local laws or workplace procedures.
1.1. Locking / Tagging Out
1. Set the Master Run switch to the STOPSYSTEM
position.
2. Rotate the 12/24 volt Battery switch to the
OFF position.
3. Lock and tag the switch and retain key.
See “Fig. 1: Locking / Tagging Out” on
page 2.
4. Switch the High Voltage Interlock switch to
the HV OFF position.
5. Lock and tag the switch and retain key.
6. Verify the low voltage and high voltage systems
are de-energized. Refer to De-Energizing
& Energizing Procedures in this
bulletin.
1.1.1. Locks / Tags Removal
1. The locks and tags shall be removed by
the installer of the locks and tags or shall
be removed under her / his supervision.
2. If the installer of the locks and tags is not
available, then her/his supervisor:
a. Ensures that the installer of the locks
and tags is not in the facility.
b. Contacts the installer to inform her/him
that the locks and tags will be removed.
c. Reminds the installer of the lock and
tag removal when she/he resumes
work.
Fig. 1: Locking / Tagging Out
????????
????????????
s145303a.svg
SMB-189 3 of 12
SERVICE MANUAL BULLETIN
SMB-189
The New Flyer vehicles described in this manual may be protected by one or more
patents and design applications or registrations in the United States and Canada,
and in other countries. Refer to “Vehicle Patent Information” in this manual.
Copyright © 2019 New Flyer Industries Canada ULC
PART TWO
2. De-Energizing & Energizing
Procedures for all Battery
Electric Vehicles equipped
with Manual Service
Disconnects (MSD)
NEVER try to connect or disconnect circuit
components such as cables, fuses,
or connectors while there is current
flowing in the circuit.
2.1. De-Energizing Procedure
1. Prepare the work area. Refer to “Service
Preparation” in your New Flyer Service
Manual for information on how to safely
prepare the work area.
2. Ensure the DC high voltage charging
cables are disconnected from the vehicle.
3. Lock Out and Tag Out the Battery Disconnect
and High Voltage Interlock switch.
Refer to 1. “Lockout / Tagout Procedure for
all Battery Electric Vehicles” on page 2 in
this bulletin for procedure.
4. Wear High Voltage Personal Protection
Equipment (PPE). Refer to “PPE Requirements”
in your New Flyer Service Manual
for guidelines.
☞NOTE:
Refer to “Equipment Requirements” in your
New Flyer Service Manual for information
on the type of multimeter required for the
following test.
5. Ensure there is no voltage on the 12/24
VDC battery bus bars. Measure in the
main fusebox between the 24V bus bar
and the ground bar. See “Fig. 2: Low Voltage
Verification” on page 3.
Fig. 2: Low Voltage Verification
????????????
????????????
????????????????????
????????????????????????????????????????
????????????????????????????????????????
????????????????
???????????????? ????????????????????????????????????????
????????????????????????????????????????
????
???????????????????????????????????????? ????????????????????????????????
????????????????????????????????????
????????????????????????
????????????????????
s145301a.svg
4 of 12 SMB-189
SERVICE MANUAL BULLETIN
SMB-189
The New Flyer vehicles described in this manual may be protected by one or more
patents and design applications or registrations in the United States and Canada,
and in other countries. Refer to “Vehicle Patent Information” in this manual.
Copyright © 2019 New Flyer Industries Canada ULC
6. Ensure there is no voltage on the High
Voltage System. Measure in the roofmounted
high voltage fuse box as follows:
a. Measure from the positive bus bar to
the negative bus bar. See “Fig. 3: High
Voltage Verification – 1” on page 4.
b. Measure from the positive bus bar to
the grounded enclosure or roof rack
structure. See “Fig. 4: High Voltage Verification
– 2” on page 5.
c. Measure from the ground bar to the
grounded enclosure or roof rack structure.
See “Fig. 5: High Voltage Verification
– 3” on page 5.
Fig. 3: High Voltage Verification – 1
????????????
????????????
????????????????????
????????????????????????????????????????
????????????????????????????????????????
????????????????
???????????????? ????????????????????????????????????????
????????????????????????????????????????
????
???????????????????????????????????????? ????????????????????????????????
????????????????????????????????????
????????????????????????
????????????????????
????????????????????????????????
????????????????????????????
????????????????????????????????
????????????????????????????
s145302a.svg
SMB-189 5 of 12
SERVICE MANUAL BULLETIN
SMB-189
The New Flyer vehicles described in this manual may be protected by one or more
patents and design applications or registrations in the United States and Canada,
and in other countries. Refer to “Vehicle Patent Information” in this manual.
Copyright © 2019 New Flyer Industries Canada ULC
Fig. 4: High Voltage Verification – 2
Fig. 5: High Voltage Verification – 3
????????????
????????????
????????????????????
????????????????????????????????????????
????????????????????????????????????????
????????????????
???????????????? ????????????????????????????????????????
????????????????????????????????????????
????
???????????????????????????????????????? ????????????????????????????????
????????????????????????????????????
????????????????????????
????????????????????
????????????????????????????????
????????????????????????????
????????????????????????????????
????????????????????????????
s145304a.svg
????????????????????????????????
????????????????????????????
????????????????????????????????
????????????????????????????
????????????
????????????
????????????????????
????????????????????????????????????????
????????????????????????????????????????
????????????????
???????????????? ????????????????????????????????????????
????????????????????????????????????????
????
???????????????????????????????????????? ????????????????????????????????
????????????????????????????????????
????????????????????????
????????????????????
s145305a.svg
6 of 12 SMB-189
SERVICE MANUAL BULLETIN
SMB-189
The New Flyer vehicles described in this manual may be protected by one or more
patents and design applications or registrations in the United States and Canada,
and in other countries. Refer to “Vehicle Patent Information” in this manual.
Copyright © 2019 New Flyer Industries Canada ULC
NEVER remove the ESS Manual Service
Disconnect plug while current is flowing
through it. The High Voltage may
create a long enough ionized gas path,
during circuit interruption, to bridge the
contacts of the switch base and therefore
continue the current flow. This ionized
gas is very hot and can cause
burns, fire and electrical shock.
Using a clamp-on current probe and
DMM, ensure that there is no current
flowing in the cables connecting to the
ESS Manual Service Disconnect plug.
7. Remove all the ESS Manual Service Disconnect
plugs as follows:
a. Press the locking tab and rotate the
MSD lever 45°. See “Fig. 6: Manual
Service Disconnect – 1” on page 6.
Fig. 6: Manual Service Disconnect – 1
b. Press the locking tab and rotate the
MSD lever to the 90° position. See “Fig.
7: Manual Service Disconnect – 2” on
page 7.
c. Remove the Manual Service Disconnects.
See “Fig. 8: Manual Service Disconnect
– 3” on page 7.
d. Install a yellow insulating cover, that is
open circuited in the Manual Service
Disconnect receptacle and lock it in
place.
☞NOTE:
Removing the Manual Service Disconnects
reduces the ESS voltage but each
battery within the ESS remains a high voltage
hazard at 88 volts.
8. Ensure that insulating covers are installed
in all ESS Manual Service Disconnect
receptacle locations.
9. Stow the removed MSDs in a locked location
to which only you have access.
10.Disconnect the high voltage cables at the
HV Junction Box on the side of the ESS.
????????????????????
????????????????
s145311a.svg
SMB-189 7 of 12
SERVICE MANUAL BULLETIN
SMB-189
The New Flyer vehicles described in this manual may be protected by one or more
patents and design applications or registrations in the United States and Canada,
and in other countries. Refer to “Vehicle Patent Information” in this manual.
Copyright © 2019 New Flyer Industries Canada ULC
Fig. 7: Manual Service Disconnect – 2
Fig. 8: Manual Service Disconnect – 3
2.2. Energizing Procedure
Perform a visual check to ensure that all
possible HV compartments are closed and
there is no debris, tools or test equipment
lying on HV terminations before energizing
the vehicle.
DO NOT touch cable terminations until
checking to ensure there is no voltage
between any of these cables and with
respect to vehicle chassis.
While connecting HV cables continuously
monitor, with the DMM, for the
inadvertent appearance of HV. If HV
appears troubleshoot why the HV
appeared and resolve before proceeding.
1. Using insulated tools, reconnect all high
voltage cables.
☞NOTE:
For the following devices, use a phase
rotation meter to ensure correct cable
sequences:
❒ Air Compressor
❒ ESS Heat Exchanger
❒ HVAC Unit
2. Reinstall high voltage junction box covers.
3. Install the ESS Manual Service Disconnect
plugs.
4. Close all HV access panels, doors, enclosures.
5. Remove the lockout / tagout from the 12/24
volt Battery Disconnect switch and turn the
switch to the ON position.
6. Remove the lock/tag from the High Voltage
Interlock switch and set the switch to the
HV ON position.
7. Set the Master Run switch to the DAY-RUN
or NIGHT-RUN position.
8. Remove “Safety Barricade” with warning
lights and “Danger High Voltage” signs
around the vehicle perimeter.
????????????????????
????????????????
s145312a.svg
????????????????????????????????????????????????????????
s145313a.svg
8 of 12 SMB-189
SERVICE MANUAL BULLETIN
SMB-189
The New Flyer vehicles described in this manual may be protected by one or more
patents and design applications or registrations in the United States and Canada,
and in other countries. Refer to “Vehicle Patent Information” in this manual.
Copyright © 2019 New Flyer Industries Canada ULC
PART THREE
3. De-Energizing & Energizing
Procedures for all Battery
Electric Vehicles without
Manual Service Disconnects
(MSD)
NEVER try to connect or disconnect circuit
components such as cables, fuses,
or connectors while there is current
flowing in the circuit.
3.1. De-Energizing Procedure
1. Prepare the work area. Refer to “Service
Preparation” in your New Flyer Service
Manual for information information on how
to safely prepare the work area.
2. Ensure the DC high voltage charging
cables are disconnected from the vehicle.
3. Lock out and Tag Out the Battery Disconnect
and High Voltage Interlock switch.
Refer to 1. “Lockout / Tagout Procedure for
all Battery Electric Vehicles” on page 2 in
this bulletin for procedure.
4. Wear High Voltage Personal Protection
Equipment (PPE). Refer to “PPE Requirements”
in your New Flyer Service Manual
for guidelines.
☞NOTE:
Refer to “Equipment Requirements” in your
New Flyer Service Manual for information
on the type of multimeter required for the
following test.
5. Ensure there is no voltage on the 12/24
VDC battery bus bars. Measure in the
main fusebox between the 24V bus bar
and the ground bar. See “Fig. 9: Low Voltage
Verification” on page 8.
6. Ensure there is no voltage on the High
Voltage System. Measure in the roofmounted
high voltage fuse box.
a. Measure from the positive bus bar to
the negative bus bar. See “Fig. 10: High
Voltage Verification – 1” on page 9.
b. Measure from the positive bus bar to
the grounded enclosure or roof rack
structure. See “Fig. 11: High Voltage
Verification – 2” on page 9.
c. Measure from the ground bar to the
grounded enclosure or roof rack structure.
See “Fig. 12: High Voltage Verification
– 3” on page 10.
Fig. 9: Low Voltage Verification
????????????
????????????
????????????????????
????????????????????????????????????????
????????????????????????????????????????
????????????????
???????????????? ????????????????????????????????????????
????????????????????????????????????????
????
???????????????????????????????????????? ????????????????????????????????
????????????????????????????????????
????????????????????????
????????????????????
s145301a.svg
SMB-189 9 of 12
SERVICE MANUAL BULLETIN
SMB-189
The New Flyer vehicles described in this manual may be protected by one or more
patents and design applications or registrations in the United States and Canada,
and in other countries. Refer to “Vehicle Patent Information” in this manual.
Copyright © 2019 New Flyer Industries Canada ULC
Fig. 10: High Voltage Verification – 1
Fig. 11: High Voltage Verification – 2
????????????
????????????
????????????????????
????????????????????????????????????????
????????????????????????????????????????
????????????????
???????????????? ????????????????????????????????????????
????????????????????????????????????????
????
???????????????????????????????????????? ????????????????????????????????
????????????????????????????????????
????????????????????????
????????????????????
????????????????????????????????
????????????????????????????
????????????????????????????????
????????????????????????????
s145302a.svg
????????????
????????????
????????????????????
????????????????????????????????????????
????????????????????????????????????????
????????????????
???????????????? ????????????????????????????????????????
????????????????????????????????????????
????
???????????????????????????????????????? ????????????????????????????????
????????????????????????????????????
????????????????????????
????????????????????
????????????????????????????????
????????????????????????????
????????????????????????????????
????????????????????????????
s145304a.svg
10 of 12 SMB-189
SERVICE MANUAL BULLETIN
SMB-189
The New Flyer vehicles described in this manual may be protected by one or more
patents and design applications or registrations in the United States and Canada,
and in other countries. Refer to “Vehicle Patent Information” in this manual.
Copyright © 2019 New Flyer Industries Canada ULC
Fig. 12: High Voltage Verification – 3
7. Using a clamp-on current probe and DMM,
ensure that there is no current flowing in
the mid-string cable or cables inside the
ESS enclosure.
☞NOTE:
The battery strings inside the ESS have a
mid-string cable identified with a label.
Removing this cable as a service disconnect
will reduce the voltage approximately
in half. Each battery remains at a high voltage
of 88V so continued caution is
required.
8. Disconnect the mid-string cable for all battery
strings located inside the ESS compartment.
See “Fig. 13: Mid-String Cable”
on page 11.
9. Remove the cable connectors as follows:
a. Pull tab #1 up. See “Fig. 14: Release
Connector Tab #1” on page 11.
b. Using an insulated flat-bladed screw
driver, press on tab #2 and release tab.
See “Fig. 15: Release Connector Tab
#2” on page 11.
c. Pull the high voltage connector off the
battery pack.
10.Cover the connector on the cable with a
locking cover to prevent it from being reinstalled
until after the service work is complete.
See “Fig. 16: Locking Cable Cover”
on page 11.
Removing the mid-string cable will
reduce the high voltage risk but not
eliminate it. Continue to use caution
while disconnecting any other cables
from the batteries or while working on
any other components within the ESS.
11.Repeat this procedure to disconnect the
most positive and most negative cable in
the battery string (or strings) located in the
ESS.
????????????????????????????????
????????????????????????????
????????????????????????????????
????????????????????????????
????????????
????????????
????????????????????
????????????????????????????????????????
????????????????????????????????????????
????????????????
???????????????? ????????????????????????????????????????
????????????????????????????????????????
????
???????????????????????????????????????? ????????????????????????????????
????????????????????????????????????
????????????????????????
????????????????????
s145305a.svg
SMB-189 11 of 12
SERVICE MANUAL BULLETIN
SMB-189
The New Flyer vehicles described in this manual may be protected by one or more
patents and design applications or registrations in the United States and Canada,
and in other countries. Refer to “Vehicle Patent Information” in this manual.
Copyright © 2019 New Flyer Industries Canada ULC
Fig. 13: Mid-String Cable
Fig. 14: Release Connector Tab #1
Fig. 15: Release Connector Tab #2
Fig. 16: Locking Cable Cover
s145307a.svg
???????????????????? ????????????????????
s145309a.svg
????????????????????????????????????
????????????????????????????????????
????????????????????????????????????????????
???????????????????? ???????????? ????
s145308a.svg
s145410a.svg
12 of 12 SMB-189
SERVICE MANUAL BULLETIN
SMB-189
The New Flyer vehicles described in this manual may be protected by one or more
patents and design applications or registrations in the United States and Canada,
and in other countries. Refer to “Vehicle Patent Information” in this manual.
Copyright © 2019 New Flyer Industries Canada ULC
3.2. Energizing Procedure
Perform a visual check to ensure that all
possible HV compartments are closed and
there is no debris, tools or test equipment
lying on HV terminations before energizing
the vehicle.
DO NOT touch cable terminations until
checking to ensure there is no voltage
between any of these cables and with
respect to vehicle chassis.
While connecting HV cables continuously
monitor, with the DMM, for the
inadvertent appearance of HV. If HV
appears troubleshoot why the HV
appeared and resolve before proceeding.
1. Using insulated tools, reconnect all high
voltage cables.
☞NOTE:
For the following devices, use a phase
rotation meter to ensure correct cable
sequences:
❒ Air Compressor
❒ ESS Heat Exchanger
❒ HVAC Unit
2. Reinstall high voltage junction box covers.
3. Close all HV access panels, doors, enclosures.
4. Remove the lockout/tagout from the 12/24
volt Battery Disconnect switch and turn the
switch to the ON position.
5. Remove the lock/tag from the High Voltage
Interlock switch and set the switch to the
HV ON position.
6. Set the Master Run switch to the DAY-RUN
or NIGHT-RUN position.
7. Remove “Safety Barricade” with warning
lights and “Danger High Voltage” signs
around the vehicle perimeter.
SMB189
https://www.nhtsa.gov/recalls?nhtsaId=10169768
https://static.nhtsa.gov/odi/tsbs/2019/MC-10169768-0001.pdf
“This site contains affiliate links for which OEMDTC may be compensated” |
- · LOCKOUT TAGOUT KIT: Lockout pouch is made of heavy duty nylon with metal belt loops for convenient tagging on the go, Compliant with OSHA's Lockout Standard
- · SAFETY PADLOCKS: The personal lockout kit contains two keyed different padlocks for reliable lockout safety, the key is one use one spare.
- LOCKOUT DEVICES: Kit contain 3 Safety Padlocks with number 1-3
2 Lockout Hasp
1 Nylon hasp
15 Loto Tags
20 Nylon ties
1 Lockout Tool Bag - · OSHA COMPLIANT LOCKOUT KIT: Compliant with OSHA's Lockout Standard designed to address risk and safety tagging in any facility
- · TWO YEARS WARRANTY: We have confidence in our product. We’ll replace it for you for free in two years. Please contact us through the contact information on the after-sales service card.
- Lockout tagout circuit breaker lockout is best used on standard height and tie-bar toggles typically found on 120 and 240 volt breakers; Best used as part of a comprehensive OSHA compliant lockout tagout safety program
- Innovative patented Grip Tight design effectively locks out circuit breakers with a simple thumb turn and then close clamping handle for a tight grip on the toggle
- Durable construction with powder coated steel and reinforced polymer for operation in harsh environments
- 5-1/8 in. (13 cm) long circuit breaker lockout with 1-3/16 in. (3 cm) height and 2-3/4 in. (7 cm) depth
- Includes one lockout tagout circuit breaker lockout; Accepts all Master Lock and American Lock safety padlock shackles and lockout hasps (padlocks and hasps sold separately)
- ✅【31 Pcs OSHA Compliant Lockout Tagout Kit】Do you work in a hazardous electrical environment and need an extra layer of safety? Well, our lockout tagout kits can help address electrical and mechanical hazards and reduce the risk of injury. 19 lockout devices will combine to protect the workplace and improve safety.
- ✅【Wide range of applications】 This safety Loto kit is a necessary addition to machinery, electrical equipment, industrial work, etc. It can effectively prevent the occurrence of electrical accidents, thus protecting the safety of workers. It can also prevent damage or disconnection problems of electrical equipment, thus saving the cost of repair and replacement and reducing the occurrence of electrical fires.
- ✅【Industrial Grade Safety Padlock】 Get ready to experience our 4 different numbered red quality padlocks that make locking out hazards a breeze. These locks are non-conductive and corrosion resistant thanks to the steel shackle, PA main body and zinc alloy cylinder. Each padlock comes with 2 keys; one for daily use and one for backup.
- ✅【Easy to manage electrical equipment】There are 3 locking clasps and 3 small circuit breaker locking in the set, when the locking of electrical equipment is completed, multiple locking can be achieved with the clasps with 6 holes thus effectively preventing unauthorized personnel from entering the electrical equipment, thus protecting the safety of the equipment.
- ✅【Safety Electrical Lockout Tag】Equipped with a tag that warns others with a bright red color. With pre-drilled mounting holes, they can be securely mounted near the machine with nylon ties, and PVC writable labels can mark hazard information. These devices are stored in a vibrant, tear-resistant EVA carrying case for greater portability and ease of use.
- 1.Lockout tagout kit:with 4 Safety Padlocks,4 Lockout Hasp ,1 Ball Valve Lockout ,1 Steel Cable Lockout ,1 Valve Lockout,1 Electrical plug Lockout,2 Nylon hasp,1 Valve Lockout ,10 Different Types of Universal Circuit Breaker Lockout,12 Loto Tags,12 Nylon ties, 1 Lockout Tool Box.
- 2.Best used for electrical lockout applications ,Locking to prevent someone from wrong operation.Handing a tag to alarm that the power source or equipment is under repaired by someone, equipment until the repair is finished and the lock is removed.
- 3.Loto Kit contains a total of 50 components to maximize your work needs.
- 4.OSHA Compliant Breaker Lockout Kit ,designed to address electrical risks in any facility.
- 5.Order with confidence. If you are not satisfied with our products, please contact us and we will reply to you within 24 hours.
- High Quality: Made of high-quality non-Conductive thermoplastic, the locks has great temperature resistance and wear resistance.
- Special Design: Compliance with "one employee, one lock, one key" directive, security and writable Label for marking
- Wide Application: The locks are designed for lockout tagout applications and features a cylinder which is reserved for safety padlocks.
- Package Content: Including 2 padlocks, each padlock is equipped with 2 keys.
- 100% Satisfied Service: Enjoy a smooth&worry-free return service within a month. Any questions feel free to contact us, we will be here for you.
- Keep your employees safe and your business compliant with these lockout/tagout tags from Harrier Hardware!
- These vinyl tags have brass grommets, clear warnings, and a writeup section that are all OSHA-compliant (1910.147)
- These tags are resistant to water, weather, and hot and cold conditions
- Each tag measures 3 inches wide by 5.5 inches tall (3" W x 5.5" T)
- Includes (40) lockout/tagout tags
- Multi-functional 68 Pcs Lockout Tagout Kit, 4 Safety Padlocks, 4 Lockout Hasp, 1 Ball Valve Lockout, 1 Steel Cable Lockout,1 Valve Lockout,1 Electrical plug Lockout, 2 Nylon hasp, 1 Valve Lockout, 12 Different Types of Universal Circuit Breaker Lockout, 20 Loto Tags, 20 Nylon ties, 1 Lockout Tool Box.
- Quality padlocks for security, the personal lockout kit contains two keyed different padlocks for reliable lockout safety, the key is one use one spare. The locks are made of non-conductive material, insulated and corrosion-resistant,making it a high-quality choice for electrical or industrial safety locking.
- Circuit Breaker, Plug, Valve Lockouts, 120/277V clamp-on with cleat, universal multi-pole circuit breaker lockout; plug LOTO device, secures most 110V up to 125V plugs; gate valve lockout for 1-inch to 2-1/2 inch handle diameter, ball valve lock for 1/2-inch to 2-3/4 inch pipes.
- Two Type Lockout Hasps & Tags, interior jaw diameter hasps with chrome-plated steel jaw & double-layered nylon-coated handle. Polypropylene hasp with 3-inch shackle length. PVC writable tags can be labeled with information for the hazard. Sturdy nylon zip ties.
- The lockout tagout kit complies with OSHA's lockout standards and Lockout tagout kits are used to shut down or lock dangerous machinery during maintenance work, ensuring no harm comes to workers. The lockout kit adopts a red design, bright and vivid color, which is more shocking to everyone's visual nerve.
- OSHA Compliant LOTO Kit - Electrical lock out tag out kits with (34) versatile lockout tagout devices, including a vibrant, tear-resistant polyester canvas carrying bag; developed and tested to ensure proper control of hazardous energy
- Safety Padlocks - (4) red locks keyed different with a non-conductive thermoplastic unibody, corrosion-resistant stainless steel shackle, key-retaining brass core cylinder, 2 keys per lock
- Plug Lock & Circuit Breaker Lockout - (1) medium-sized plug LOTO device, secures most 110V up to 125V plugs; (3) 120/277V clamp-on with cleat, (2) universal multi-pole breaker lock
- LOTO hasps & Lockout Tags - (2) group lockout hasp with chrome-plated steel jaw and industrial-grade nylon-coated handle, (1) non-conductive polypropylene electrical hasp; (20) 32-mil weather-resistant PVC vinyl danger do not operate tags, seamless notation using permanent markers or wax/grease pencils, (30) nylon cable ties
- Trusted Safety Supplier - TRADESAFE is an established USA based and owned industry expert and reliable safety partner for LOTO compliance supplies
- 1.Compliant to OSHA-compliant safe programs standards for lock Out Tag Out Stations and lockout tagout Devices
- 2. Each lock has two keys: a spare key can prevent the loss of the key from causing unnecessary damage.Please check with the security supervisor before purchase that a spare key is allowed.
- 3. Each lock and key has a corresponding number: convenient for your LOTO security management, the number is laser printed, very clear and not easy to erase.
- 4. Standard industrial size: 1-1/2 in. Wide lock body;1/4 in. diameter shackle with 1-1/2 in. length, 25/32 in. width.
- 5. 30 locks, two keys for each lock. 30 *LOTO Lockout Tagout Tags. Every key is different. If you are not satisfied with our products, please contact us and we will reply to you within 24 hours.
- Package includes 10 pack lockout tagout locks, one key per lock. Standard industrial size: 1.4 inches wide lock body; 1/4 inches diameter shackle with 1.5 inches in length, 0.8 inches width.
- Our lockout tagoutlocks are highly durable, featuring a nonconductive nylon body and stainless-steel shackle. The padlock lockout key, with its high-grade brass core cylinder, ensures the key remains retained until the shackle is locked, preventing accidental unlocking.
- Safety padlock is designed to insert the key in both sides, so there is no need to choose the direction of inserting the lock hole, which is more convenient to use. Key retention function design, the key cannot be removed if the lock is unsuccessful. Prevent loss of locks.
- The front of the safety padlock has a high-quality label, which is waterproof and corrosion resistant, reminding staff of danger and reducing the occurrence of safety accidents; a writable AVY label is attached to the back of the padlock for easy management.
- Each lock and key has a corresponding number: convenient for your LOTO security management, the number is laser printed, very clear and not easy to erase. Great for lock Out Tag Out Stations and lockout tagout Devices.
Last update on 2024-04-20 / Affiliate links / Images from Amazon Product Advertising API
This product presentation was made with AAWP plugin.