“This site contains affiliate links for which OEMDTC may be compensated” |
May 23, 2024 NHTSA CAMPAIGN NUMBER: 24V362000
Damaged Cylinder Feeder Tube May Leak Oil
Uncontrolled movement of the boom can increase the risk of injury.
NHTSA Campaign Number: 24V362
Manufacturer Altec Industries, Inc.
Components EQUIPMENT
Potential Number of Units Affected 1,128
Summary
Altec Industries, Inc. (Altec) is recalling certain 2020-2024 Altec LR7 and LR8 aerial devices. The hydraulic cylinder feeder tube routed near the cylinder rest bracket may become damaged and leak oil, which can result in uncontrolled boom movement.
Remedy
Altec will replace the cylinder rest pad and the feeder tube if necessary, free of charge. Owner notification letters are expected to be mailed July 22, 2024. Owners may contact Altec customer service at 1-877-462-5832. Altec’s number for this recall is CSN-3142.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.nhtsa.gov.
Chronology :
On April 12, 2024, Altec identified units in production that had contact between the feeder tube and the cylinder rest bracket. Altec Quality Assurance initiated an investigation to determine the root cause, scope, and affected units. On April 17, 2024, a hold was placed on all production units until the investigation was complete. Production changes were made on April 25, 2024, to remedy all units contained at the plant and future production. On May 6, 2024, a potential field action investigation was opened to determine if units in the field could have the specific supplier cylinder where the feeder tube could contact the bracket. After reviewing the production and supplier records on May 17, 2024, Altec determined that a potential defect could exist on certain LR7 and LR8 units. There were no warranty claims or field reports identified. There have been no accidents, injuries, or deaths related to this issue.
5 Affected Products
Vehicle
MAKE | MODEL | YEAR |
ALTEC | AERIAL DEVICE | 2020-2024 |
2 Associated Documents
Recall 573 Report
RCLRPT-24V362-5998.PDF 214.338KB
Recall Acknowledgement
RCAK-24V362-6836.pdf 645.389KB
Latest Recalls Documents
https://www-odi.nhtsa.dot.gov/acms/cs/documentList.xhtml?docId=24V362&docType=RCL
- Formulated with premium base stocks for added resistance to thermal breakdown
- Outstanding wear protection
- Excellent resistance to system rust and oil oxidation
- Maintains excellent water separating properties
- Excellent foam control and air release deliver consistent system operation
- Formulated with premium base stocks for added resistance to thermal breakdown
- Outstanding wear protection
- Excellent resistance to system rust and oil oxidation
- Maintains excellent water separating properties
- Excellent foam control and air release deliver consistent system operation
- Formulated with highly refined group ii base stocks for added resistance to thermal breakdown
- Superior wear protection to protect critical components
- Excellent frictional properties for smooth-shifting, excellent anti-shudder performance
- J20c equivalent, protection against varnish and sludge formation
- Superior thermal stability and oxidation resistance, good seal compatibility
- Meets and exceeds all OEM specifications for power shift transmissions
- Extends equipment and fluid life
- Reduces downtime and major overhaul
- Formulated with premium base stocks for added resistance to thermal breakdown
- Outstanding wear protection
- Excellent resistance to system rust and oil oxidation
- Maintains excellent water separating properties
- Excellent foam control and air release deliver consistent system operation
- Reduces the operating temperature of hydraulic systems
- Conditions old seals and O-rings to stop and prevent future leaks
- Well suited for use in equipment with wet brakes
- Removes varnish and restores pressure for more efficient operation
- Compatible with both synthetic and conventional hydraulic fluids
- MULTI-PURPOSE & ALL SEASON: A premium transmission-hydraulic fluid recommended for the complex lubrication systems of modern tractors, including industrial models. In these systems, the same lubricant may serve the hydraulic system, torque converter, transmission, power take-off, differential, power steering, and wet brakes.
- SPECIFICATIONS: Our tractor hydraulic fluid meets the following manufacturers specifications: (J20C, JD303), (Q-1826), (Improved power fluid 821XL), (ESN-M2C134-D, FNHA-2-C-201), (M1135, M1141, M1143), (Type 55), (JIC-143,144, 145, MS1206,127, 1209, 1210, TCH), (Fluids), (TO-2, MTD), (Bus Automatic Transmission Fluid), (UDT), (B6), (WB 101).
- APPLICATIONS: Included in the above applications, this universal tractor fluid also meets most other manufacturers' specifications for transmission hydraulic fluid. It can be used for makeup or refill in almost all tractor hydrostatic, hydraulic jack oil, transmission oil, differential fluid, and other systems involving common lube oil sumps.
- BENEFITS: This tractor transmission oil gives all-season protection. It flows readily at low temperatures due to its low-temperature viscosity and pour point, and yet retains its body at high temperatures due to a high viscosity index. Other benefits include anti-foam, anti-rust, anti-wear, extreme pressure, seal protection, oxidative and thermal stability, and controlled frictional characteristics.
- PREMIUM LUBRICANTS: Presidential Engineered Lubricants offers premium machine oils, lubricants, and sealants for various industries. Founded in 1877, we're an employee-owned company dedicated to crafting high-quality products at our UO facility, with customer satisfaction as our top priority.
Last update on 2024-06-10 / Affiliate links / Images from Amazon Product Advertising API
This product presentation was made with AAWP plugin.
SEOCONTENT-START
OMB Control No.: 2127-0004
Part 573 Safety Recall Report 24V-362
The information contained in this report was submitted pursuant to 49 CFR §573
Manufacturer Name : Submission Date :
Altec Industries, Inc. MAY 23, 2024 NHTSA Recall No. : 24V-362 Manufacturer Recall No. : CSN 3159 Manufacturer Information :
Manufacturer Name : Altec Industries, Inc.
Address : 210 Inverness Center Drive Birmingham AL 35242
Company phone : 205 991 7733
Population :
Number of potentially involved : 1,128 Estimated percentage with defect : 50 %
Vehicle Information : Vehicle 1 : 2020-2024 Altec LR7; LR8 Vehicle Type :
Body Style :
Power Train : NR
Descriptive Information : Altec determined the recall population using dates for the affected components provided by the supplier and a review of production records.
Production Dates : OCT 21, 2020 – APR 24, 2024
VIN Range 1 : Begin : NR End : NR Not sequential Description of Defect :
Description of the Defect : The feeder tube on certain LR7 and LR8 upper boom cylinders could contact a cylinder rest bracket on the lower boom. If the feeder tube is in contact with the bracket, wear or damage to the tube could cause a leak over time.
FMVSS 1 : NR FMVSS 2 : NR
Description of the Safety Risk : If the feeder tube leaks, the cylinder could lose its load-holding capability. If the cylinder cannot hold a load, it creates a risk of uncontrolled boom movement that could result in serious injury or death to the operator or others nearby.
Description of the Cause : NR Identification of Any Warning
that can Occur : A Preventive Maintenance inspection or preoperational inspection could identify contact between the feeder tube and the bracket or a potential oil leak at the cylinder feeder tube.
Involved Components : Part 573 Safety Recall Report 24V-362 Page 2 Component Name 1 : Hydraulic Cylinder Component Description : Hydraulic Cylinder Component Part Number : 991054696 Component Name 2 : Hydraulic Cylinder Component Description : Hydraulic Cylinder Component Part Number : 990879921 Supplier Identification : Component Manufacturer
Name : Monarch Industries Address : 51 Burmac Rd
Winnipeg Foreign States R2J 4J3
Country : Canada Chronology :
On April 12, 2024, Altec identified units in production that had contact between the feeder tube and the cylinder rest bracket. Altec Quality Assurance initiated an investigation to determine the root cause, scope, and affected units. On April 17, 2024, a hold was placed on all production units until the investigation was complete. Production changes were made on April 25, 2024, to remedy all units contained at the plant and future production. On May 6, 2024, a potential field action investigation was opened to determine if units in the field could have the specific supplier cylinder where the feeder tube could contact the bracket. After reviewing the production and supplier records on May 17, 2024, Altec determined that a potential defect could exist on certain LR7 and LR8 units. There were no warranty claims or field reports identified. There have been no accidents, injuries, or deaths related to this issue. Description of Remedy :
Description of Remedy Program : Replacing the current ½ inch tall cylinder rest pad with a new 1-inch tall
rest pad will provide sufficient clearance for the specific cylinders. For units with a damaged feeder tube, a new cylinder and 1-inch rest pad would be provided. When presented for repair, the recall remedy will be completed free of charge. The Altec Warranty Policy covers the recall remedy, including cases requiring reimbursement for the cost of obtaining a pre-notification remedy of the problem associated with this recall. The information contained in this report was submitted pursuant to 49 CFR §573 Part 573 Safety Recall Report 24V-362
Page 3
The information contained in this report was submitted pursuant to 49 CFR §573
How Remedy Component Differs from Recalled Component : Identify How/When Recall Condition was Corrected in Production :
A 1-inch tall rest pad is ½ an inch taller than the original one installed. This will allow the cylinder to rest ½ an inch higher and create sufficient space between the feeder tube and bracket.
The cylinder rest bracket was revised to create more clearance between it and the cylinder, eliminating any potential interferences. The cylinder manufacturer is moving the retract port location on the feeder tube 7/8 inch to match the port location of other suppliers, creating additional clearance. Recall Schedule :
Description of Recall Schedule : Altec will issue CSN-3159 to the owners of the affected units. Altec does
not have a dealer network and issues letters to owners only.
Planned Dealer Notification Date : JUL 22, 2024 – JUL 22, 2024
Planned Owner Notification Date : JUL 22, 2024 – JUL 22, 2024
* NR – Not Reported
**************************************************************************************************************
**************************************************************************************************************