November 13, 2023 NHTSA CAMPAIGN NUMBER: 23V766000
AC Wiring May Become Damaged and Cause a Fire
Electrical arcing may cause sparks and increase the risk of a fire.
NHTSA Campaign Number: 23V766
Manufacturer Triple E Recreational Vehicles
Components ELECTRICAL SYSTEM
Potential Number of Units Affected 37
Summary
Triple E Recreational Vehicles (Triple E) is recalling certain 2023-2024 Triple E Wonder W24RTB, W24RL, and W24FTB motorhomes. The wire insulation on the 120-volt wire routed to the air conditioner may become damaged, which can cause electrical arcing.
Remedy
Dealers will install a grommet and 2 screws, free of charge. Owner notification letters are expected to be mailed November 21, 2023. Owners may contact Triple E customer service at 1-877-992-9906. Triple E’s number for this recall is CA#10438-1.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.nhtsa.gov.
SOP12388
Recall QAAR 10438 Truma Air
Conditioner Power Supply Grommet
Remove both side panels on the air conditioner diffuser housing by sliding sideways.
Remove the 6 hex drive screws from the diffuser housing.
Verify the yellow 12/2 NMD wire is missing a grommet where it runs into the roof frame.
If grommet is present no corrective action is required, proceed to step #7.
If grommet is missing, use the split to install the grommet over top of the 12/2 wire and insert into the hole in roof frame .
Secure grommet in place with the two self-tapping screws into the frame.
Reinstall the diffuser housing starting all the hex drive screws by hand to prevent cross threading.
Torque each hex head to 15inch lbs.
Reinstall both side panels to the side of the air diffuser.
Chronology :
ON OCTOBER 25/2023 AN INHOUSE AUDIT WAS CONDUCTED IT WAS NOTICED THAT THE TRUMA AIR CONDITIONER 120V WIRING WAS WIRED THROUGH THE ALUMINUM ROOF FRAME WITH NO PROTECTION FROM THE METAL EDGE. THE ROOF DRAWINGS DID NOT INCLUDE THE WIRING CHANNELS FOR THE INSTALLER TO FOLLOW CAUSING INCONSISTENCIES IN THE INSTALLATION PROCEDURE OF THE WIRING FOR THE AIR CONDITIONER. A MISCOMMUNICATION ON WHO WAS RESPONSIBLE FOR PLACING THE GROMMET DURING THE PROCESS. THE WIRING IS COMPLETED DURING THE PRODUCTION PROCESS AND NOT WHEN THE AIR CONDITIONER IS INSTALLED ON THE ROOF.
2 Affected Products
Vehicle
MAKE | MODEL | YEAR |
TRIPLE E RV | WONDER | 2023-2024 |
8 Associated Documents
Recall 573 Report – 11/15/2023
RCLRPT-23V766-2054.PDF 215.202KB
Recall Acknowledgement
RCAK-23V766-2417.pdf 646.191KB
Defect Notice 573 Report
RCLRPT-23V766-7612.PDF 215.188KB
Miscellaneous Document – CA#10438 – Truma AC Wire Grommet – SOP12388
RMISC-23V766-6131.pdf 980.466KB
Manufacturer Notices(to Dealers,etc)
RCMN-23V766-6005.pdf 563.548KB
Recall 573 Report – 11/20/2023
RCLRPT-23V766-7252.PDF 215.208KB
Miscellaneous Document – Recall CA#10438-1 – Return Form
RMISC-23V766-5939.pdf 77.424KB
ISSUED Owner Notification Letter(Part 577)
RCONL-23V766-8599.pdf 1018.285KB
Latest Recalls Documents
https://www-odi.nhtsa.dot.gov/acms/cs/documentList.xhtml?docId=23V766&docType=RCL
- 16 gauge wire - in 6 Bright colors rolls of 100ft 16 gauge auto wire
- 16 gauge auto wire single conductor, remote, turn on, hook up wire, stranded copper clad aluminium 16 gauge wire
- Flexible 16 gauge auto wire, insulated 16 gauge wire, and jacketed in PVC; Rated 158 degrees Fahrenheit (6 to 80 Volts)
- 16 Gauge auto wire perfect for car audio, home theatre, automotive; Use this 16 gauge wire with any 12 Volt or home project
- THIS IS NOT AMERICAN 16 AWG WIRE, IT’S HIGH QUALITY 16 GAUGE AUTO WIRE FOR A GREAT PRICE!
- 14 gauge wire - in 6 Bright colors rolls of 100ft 14 gauge auto wire
- 14 gauge auto wire single conductor, remote, turn on, hook up wire, stranded copper clad aluminum 14 gauge wire. The advantage of the copper clad aluminum wire is lighter and more flexible than copper wire.
- Flexible 14 gauge auto wire, insulated 14 gauge wire, and jacketed in PVC; Rated 158 degrees Fahrenheit (6 to 80 Volts)
- 14 Gauge auto wire perfect for car audio, home theatre, automotive; Use this 14 gauge wire with any 12 Volt or home project
- THIS IS NOT AMERICAN 14 AWG WIRE, IT’S HIGH QUALITY 14 GAUGE AUTO WIRE FOR A GREAT PRICE!
- [Copper Clad Aluminum (CCA)] CCA wire offers the same signal frequency and reliability in terms of corrosion resistance to copper wire. The advantage of the CCA wire is lighter and more flexible than copper wire. The cost of CCA vs Oxygen free copper is much lower and you can enjoy the same functions and reliability as copper wire without paying the extra cost for the installation.
- [Wide Compatibility] Electrical wire widely used in monochromatic LED strips, model cars, marine, low voltage wires, light bulbs, power/ground for indoor lighting, low loss home appliances or car audio installations, etc.
- [Low Voltage Wire] electrical wire is made of 16 AWG 100FT with red and black 2 conductors and high quality PVC jacket, good conductivity, high mechanical strengthfeatures, flame retardant, anti-aging, acid and alkali resistance and dampproof.
- [Perfect Performance] Wire operating temperature rating of -20℃ of 70℃ respectively. 2 conductor wire is flexible, durable and easy to bend, so that you can better separate the two wires in use without exposing the wires inside.
- [Best Service] Please feel free to contact us if you have any problems with our automotive wire, we will make every effort to help you.
- Package Include: 16 gauge 6 different colors each 10 Feet / 3.05 Meter spools (black, red, blue, white, green, yellow, total 60ft), also packed both of Diameter 3.2mm HEAT SHRINK TUBINGS (3pcs X 6colors = 18pcs total) and 4 inch WIRE TIES (3pcs X 6colors = 18pcs total).
- SPECIFICATIONS -Silicone Wire 16 AWG Hook-Up Wire is made of Silicone tinned copper conductor with a Silicone sheath, OD=3mm; 600 volts voltage rating, Silocone Insulation that can withstand heats of up to 200 degree C.
- FEATURES - Good abrasion resistance electric wire provides high flexibility and resistance to substances such as oil,solvents and chemicals.
- EASY TO USE - easy to handling, stripping, crimping terminals and welding.
- Application - Fermerry Silicone Wires Are Widely Used in LED lighting, Perfect for prototyping circuits and ideal as breadboard hookup wires.
- 16 Gauge Copper-Clad aluminum primary wires, 6*50FT color rolls pack(300 FT in total)
- Aluminum core wire, 10% copper coating
- Flexible PVC, PVC Rated to 105°C, 6-80VDC, Stay organized with 6 different colors
- Alternative to OFC copper wire. Achieves 80% conductivity.
- Ideal for 12V automotive hookup, Car Audio, indoor, interior use
- COPPER CLAD ALUMINUM (CCA) - Our primary cable CCA wire is the most economical option for choosing power or ground wire and is a great conductor of power. Copper coated aluminum gives you an economic power cable with excellent power transfer. Systems that require more power should use ofc cable wiring.
- POWER / GROUND WIRE SET - Our bundled power wire set is great for a car amplifier or subwoofer or to be used as a ground wire on your electric wire installs. Use for many different applications such as indoor lighting, car radio, automotive, lighting, car speakers, power cables, 12v power inverter, ground wire, or welding cable.
- SOFT TOUCH JACKET - Soft touch jacket design designed for the electrical and auto repair installer in mind. Strong, yet durable pvc jacket that is best for indoor use but has flexibility, elasticity, and impact resistance built in.
- EASY POLARITY IDENTIFICATION - Easy color coded ground wire helps with installation to let you know which cable should connect to the terminal. Making a polarity error could cause serious damage to your audio equipment. Package Contents: includes 1 x Black wire and 1 x Red wire as an electrical wire kit.
- WIDE COMPATIBILITY - Also known as power wire, ground wire, trolling motor wire, automotive wire, speaker wire, car radio wire, amp wire, electrical wire, or welding wire designed for up to 80v voltage. We have many gauge wires to choose from, such as 10awg, 12awg, 14awg, 16awg with black, red, blue, yellow wire color options and 50ft, 100ft, 150ft, 200ft lengths
- True 14-gauge wire with spool from TyumenDirect lets you easily connect your speakers to amplifiers or receivers. That is ideal for all single color LED strip light, low voltage single color led strip, light bulb, lamp.
- It is widely used for various DC electrical hookups, low voltage cables, 12V DC, 24V DC, low-loss in-home or car stereo installs. Great for in-home applications as well as automotive, schools, churches, auditoriums or business settings.
- The jacket material is flexible and environmental friendly PVC. Well protected against dampness, such as convenient peel and cut.
- Wire comes wrapped around a hard plastic spool that makes dispensing convenient. 2 jacket colors make for quick and easy to distinguish the polarity & numbered markings for accuracy.
- 100 ft / spool (100FT Red & 100FT Black), actual length is 31m, longer than described, stranding structure makes it flexible and easy to install, cut into any length based on needs.
- ✅【HIGHLY CONDUCTIVE】NAOEVO electrical wire uses high-precision oxygen free tinned copper, outside diameter of the Jacket is 2.7mm Typ, and 41 strands of 0.14mm tinned copper wire is inside each circuit, which has lower resistance and higher conductivity.
- ✅【PRODUCT SPECIFICATION】18 AWG wire waterproof level: IP68. Rated voltage: 600V(also can for 5V 12V 24V up to 600V). Rated working temperature up to -40°F/ 248°F. Flame retardant grade: V-1
- ✅【BUILT TO LAST】2 Conductor 18 gauge wire is insulated/jacketed with high quality PVC, excellent chemical and oxidation resistance, and 16 packs of heat-shrinkable tubes & 4 packs of cable ties. These tubes can Protect wires and cables from damage caused by wear and tear, abrasion, and moisture.
- ✅【EASY TO USE】The 18/2 electric wire is lightweight, thin, soft can be bent arbitrarily, and is easy to strip, weld, crimp terminals, connect, cut, and wrap around necessary components enough to fit into tight spaces.
- ✅【APPLICATION】Low voltage wire, Speaker wire, LED light power cord, indoor light cable, automotive wire, landscape light wire, lamp wire, LED light wire, marine wire, electronic product internal cable, and so on.
- Big Quantity: this is a standard 10 pcs 100 ft 14 gauge electrical wire, 10 wires are 14 gauge and the same length; There are 10 colors of red, black, blue, yellow, white, green, purple, gray, orange, and brown, which can be easily applied separately from the circuit
- Reliable Copper Clad Aluminum (CCA): our 14 gauge AWG wire Specifically designed for automotive applications and audio speaker wiring, 12V auto wire is made of top quality Copper Clad Aluminum (CCA), which brings reliable and efficient power delivery for your 12 volt power requirements; Our CCA cables provide nice power transmission performance while remaining cost effective, giving you a good balance between quality and economy
- High Temperature Resistance: these copper clad aluminum CCA wire are heat resistant to 221 °F/ 105 °C, and each reel contains 100 feet of 14 gauge single conductor with a core of copper clad aluminum stranded wire, about 0.02 cm diameter/ strand, 54 strands; Suitable for a variety of applications from 6 volts to 80 volts, not suitable for building and home 110/ 220 V Alternating Current wiring
- Durable PVC Jacket: our 14 gauge bulk automotive wire PVC jacket is designed for automotive use, it is flexible, elastic and impact resistant; The boot protects the wires from shock and abrasion while remaining flexible for easy installation in a variety of applications
- Wide Applications: this low voltage auto wire can be widely applied for remote openers, car stereos, trailer lighting, motorcycles, RV boats, LED lights and more, suitable for many of your basic wiring needs
Last update on 2024-06-11 / Affiliate links / Images from Amazon Product Advertising API
This product presentation was made with AAWP plugin.
SEOCONTENT-START
1 2 3
4 5 6
7 8 9
#2
•
•
•
•
6mm
SOP12388
TRIPLE E
RECREATIONAL VEHICLES
Recall QAAR 10438 Truma Air
Conditioner Power Supply Grommet
Supplied Items:
1ea. 3/4″ x 50mm tall
Split Grommet 118-6502
2ea. #8x¾” self tapping
screws 141-0092
15in.-lbs.
–
0
….
Tools required:
Cordless drill
#2 square driver bit
6mm hex drive
socket
Inch pound torque
wrench
Verify the yellow
12/2 NMD wire is
missing a grommet
where it runs into
the roof frame.
If grommet is
present no
corrective action is
required, proceed to
step #7.
Reinstall the diffuser housing starting all the hex drive screws by hand
to prevent cross threading.
Torque each hex head to 15inch lbs.
Remove both side panels on the air conditioner diffuser housing by
sliding sideways.
If grommet is missing, use the split
to install the grommet over top of
the 12/2 wire and insert into the
hole in roof frame .
Reinstall both side panels to the side of the air diffuser.
Department: 32
People Required: 1
Time to Complete: 0.30 hours
Date Created: Nov. 08/23
Date Revised: Rev#:
Created by Initial: GK Verified: BH Page 1 of 1
Remove the 6 hex drive screws from the
diffuser housing.
Secure grommet in place with the two self-tapping screws into the
frame.
LE ‘SURE
TRll.\!’ E:L YA Nl ‘.5
Contact Leisure Travel Vans Customer Service/Warranty for
questions or technical assistance at:
1-877-992-9906
Or
Recalls@Tripleerv.com
**************************************************************************************************************
RECALL NOTIFICATION CA#10438-1 – RETURN FORM
Please complete this form indicating Recall Notification CA#10438-1 has been performed in accordance with this Recall. E-mail completed form to recalls@tripleerv.com
Customer Name: «Owner_Name»
Serial # «VIN»
Coach Serial #«Serial»
Address (if different)_________________________________________
__________________________________________________________
Date Recall Completed _______________________________________
Signature of Customer: ______________________________________
Brad Wall
Customer Service / Warranty Manager
**************************************************************************************************************
LEISURE
TRAVEL VANS
Tri ple E Recreational Vehicles
A Di vision of Triple E Canada Ltd.
P: 204 325 4361
F: 204 325 5241
301 Roblin Blvd .
P.O . Box 1230
Winkler, Manitoba CA
R6W 4C4
U.S . Mai lin g :
P.O. Box 68
Walhalla, ND 58282
LE I SUR EVANS.COM
TRIPLE ERV.COM
IMPORTANT SAFETY RECALL
«Owner Name»
«Address 1 »
«Address2»
«Address3 », «Prov» «Postal Code»
“This notice applies to your vehicle, «Unit»
VIN #«VIN»
Coach Serial #«Serial»
Triple E Recreational Vehicles Recall CA#l0438-l
November 23, 2023
NHTSA #23V766
This notice is sent to you in accordance with the requirements of the National
Traffic & Motor Vehicle Safety Act. Triple E Recreational Vehicles has decided
that a defect which relates to motor vehicle safety exists in certain 2023 & 2024
Wonder W24RTB, W24FTB & W24RL motorhomes manufactured between May
5, 2023 and October 18, 2023
Description of Defect:
The 120V wiring for the Truma air conditioner, is being routed through the roof
aluminum framing. The wires may become worn from rubbing on the raw metal
edge causing an arcing hazard. This could cause a small spark and cause a possible
fire and bodily injury.
To Have This Modification Performed:
Please contact your closest Triple ERV dealer or approved RV service center to
have this recall performed at no charge to you. Your dealer will install a grommet
over the wiring and attach it to the aluminum framing. The time needed to perform
the recall is approximately 20 minutes. If you choose to have this Recall
performed by a service center other than your dealer, prior authorization is
required. When the issue has been corrected sign the enclosed return form and
email to recalls@tripleerv.com
If you had this repair performed before you received this letter, you may be
eligible to receive reimbursement for the cost of obtaining a pre-notification
remedy of the problem associated with this recall.
1 of2
For more information contact Triple ERV/Leisure Travel Vans at 1-877-992-
9906 Customer Service/ Warranty department or by e-mail
recalls@tripleerv.com in the subject line “Recall CA#l0438-1”.
What if you are a Lessor?
Federal law requires that you forward a copy of this safety recall notice to the
lessee within ten working days.
If you no longer own this vehicle, please complete the return form stating “No
Longer Own this Vehicle” or provide the new owners contact information and
submitting to Customer Service at recalls@tripleerv.com
For U.S. Residents
If Triple E Recreational Vehicles fails or is unable to remedy this potential defect
without charge, you may submit a written complaint to the Administrator,
National Highway Traffic Safety Administration, 1200 New Jersey Ave. SE,
Washington, DC 20590 or call the toll free Vehicle Safety Hotline at 1-888-327-
4236; (TTY: 1-800-424-9153) or go to http://www.safercar.gov
We regret the inconvenience this Recall may cause you but want you to have
complete satisfaction with your Leisure Travel Vans product. Thank you for your
anticipated assistance and please do not hesitate to contact us should you require
additional information.
Sincerely,
Brad Wall
Customer Service / Warranty Manager
BW/wcw
Enclosures
1 – SOP12388 (Standard Operating Procedure)
I -Grommet
2 – Self-tapping screws
2 of2
**************************************************************************************************************
LEISURE
TRAVEL VANS
Triple E Recreational Vehicles
A Di vision of Triple E Canada Ltd.
P: 204 325 4361
F: 204 325 5241
301 Roblin Bl vd.
P.O. Box 1230
Winkler, Manitoba CA
R6W 4C4
U.S. Mailing:
P.O. Box 68
Walh alla , ND 58 282
LEI SUR EVANS.COM
TRIPLEERV.COM
IMPORTANT SAFETY RECALL
«Dealer»
“This notice applies to this vehicle, «ProductLine»
VIN #«Vin»
November 20, 2023
Coach #« UNIT CoachID»
Triple E Recreational Vehicles Recall CA#l0438-l NHTSA #23V766
This notice is sent to you in accordance with the requirements of the National
Traffic & Motor Vehicle Safety Act. Triple E Recreational Vehicles has
decided that a defect which relates to motor vehicle safety exists in certain 2023
& 2024 Wonder W24RTB, W24FTB & W24RL motorhomes manufactured
between May 5, 2023 and October 18, 2023
Description of Defect:
The 120V wiring for the Truma air conditioner, is being routed through the roof
aluminum framing. The wires may become worn from rubbing on the raw
metal edge causing an arcing hazard. This could cause a small spark and cause
a possible fire and bodily injury.
To Have This Modification Performed:
We request your assistance to have this safety issue corrected. Follow
SOP12388 included in this mailing to install a grommet over the wiring for the
Truma air conditioner.
For reimbursement submit a warranty application for,
Labour to perform this Recall: 0.5 hrs/ unit
1 of2
For more information contact Triple ERV/Leisure Travel Vans at 1-877-
992-9906 Customer Service/ Warranty department or by e-mail
recalls@tripleerv.com in the subject line “Recall CA#l0438-1”.
Thank you for your anticipated assistance and please do not hesitate to contact
us should you require additional information.
Sincerely,
Brad Wall
Customer Service / Warranty Manager
BW/wcw
Enclosures
1 – SOP12388 (Standard Operating Procedure)
1 – Grommet
2 – Self-tapping screws
2 of2
**************************************************************************************************************
OMB Control No.: 2127-0004
Part 573 Safety Recall Report 23V-766
The information contained in this report was submitted pursuant to 49 CFR §573
Manufacturer Name : Triple E Recreational Vehicles
Submission Date : NOV 13, 2023
NHTSA Recall No. : 23V-766
Manufacturer Recall No. : CA#10438-1
Manufacturer Information :
Manufacturer Name : Triple E Recreational Vehicles
Address : PO Box 1230 Winkler MB
Canada 00 R6W 4C4
Company phone : 204-325-4361
Population :
Number of potentially involved : 37
Estimated percentage with defect : 100 %
Vehicle Alterer Information :
Vehicle 1 : 2023-2024 WONDER W24RTB
Descriptive Information : CERTAIN WONDER MODELS HAVE THE TRUMA AIR CONDITIONER INSTALLED
ON THE ROOF DURING THE SUB-ASSEMBLY PROCESS AND THE WIRING
CONNECTIONS ARE COMPLETED ON THE PRODUCTION LINE, THEY DON’T
HAVE DUCTED ROOF VENTS. THE OTHER MODEL IS INSTALLED AND WIRING
CONNECTIONS COMPLETED ON THE PRODUCTION LINE, HAVING DUCTED
ROOF VENTS.
UNITS AFFECTED 20
Production Dates : MAY 05, 2023 – OCT 18, 2023
Vehicle 2 : 2023-2024 WONDER W24FTB
Descriptive Information : CERTAIN WONDER MODELS HAVE THE TRUMA AIR CONDITIONER INSTALLED
ON THE ROOF DURING THE SUB-ASSEMBLY PROCESS AND THE WIRING
CONNECTIONS ARE COMPLETED ON THE PRODUCTION LINE, THEY DON’T
HAVE DUCTED ROOF VENTS. THE OTHER MODEL IS INSTALLED AND WIRING
CONNECTIONS COMPLETED ON THE PRODUCTION LINE, HAVING DUCTED
ROOF VENTS.
UNITS AFFECTED 5
Production Dates : MAY 05, 2023 – OCT 18, 2023
Part 573 Safety Recall Report 23V-766 Page 2
The information contained in this report was submitted pursuant to 49 CFR §573
Vehicle 3 : 2023-2024 WONDER W24RL
Descriptive Information : CERTAIN WONDER MODELS HAVE THE TRUMA AIR CONDITIONER INSTALLED
ON THE ROOF DURING THE SUB-ASSEMBLY PROCESS AND THE WIRING
CONNECTIONS ARE COMPLETED ON THE PRODUCTION LINE, THEY DON’T
HAVE DUCTED ROOF VENTS. THE OTHER MODEL IS INSTALLED AND WIRING
CONNECTIONS COMPLETED ON THE PRODUCTION LINE, HAVING DUCTED
ROOF VENTS.
UNITS AFFECTED 12
Production Dates : MAY 05, 2023 – OCT 18, 2023
Description of Defect :
Description of the Defect : THE 120V WIRING ROUTED TO THE TRUMA AIR CONDITIONER THROUGH
THE ALUMINUM ROOF FRAME MAY NOT HAVE A GROMMET TO PROTECT
FROM THE RAW METAL EDGE.
FMVSS 1 : NR
FMVSS 2 : NR
Description of the Safety Risk : THE WIRE INSULATION MAY BECOME WORN FROM RUBBING ON THE
METAL EDGE OF THE ALUMINUM TUBING, CAUSING AN ARCING HAZARD.
THIS COULD CAUSE A SMALL SPARK, AND CAUSE A POSSIBLE FIRE AND
BODILY INJURY.
Description of the Cause : DURING A CHANGE FROM MODEL YEAR THE ROOF DRAWINGS HAD THE
WIRE CHANNELS ACCIDENTLY OMITTED. THE INSTALLER OF THE WIRING
WAS NOT AWARE THAT A GROMMET HAD TO BE INSTALLED ON THE METAL
EDGE OF THE ALUMINUM TUBING TO PROTECT THE WIRING.
Identification of Any Warning
that can Occur :
THERE COULD BE A POSSIBLE SMELL OF WIRE INSULATION BURNING OR
THE TRUMA AIR CONDITIONER WILL NOT HAVE POWER.
Involved Components :
Component Name : NR
Component Description : NR
Component Part Number : NR
Supplier Identification :
Component Manufacturer
Part 573 Safety Recall Report 23V-766 Page 3
The information contained in this report was submitted pursuant to 49 CFR §573
Name : NR
Address : NR
NR
Country : NR
Chronology :
ON OCTOBER 25/2023 AN INHOUSE AUDIT WAS CONDUCTED IT WAS NOTICED THAT THE TRUMA AIR
CONDITIONER 120V WIRING WAS WIRED THROUGH THE ALUMINUM ROOF FRAME WITH NO PROTECTION
FROM THE METAL EDGE. THE ROOF DRAWINGS DID NOT INCLUDE THE WIRING CHANNELS FOR THE
INSTALLER TO FOLLOW CAUSING INCONSISTENCIES IN THE INSTALLATION PROCEDURE OF THE WIRING
FOR THE AIR CONDITIONER. A MISCOMMUNICATION ON WHO WAS RESPONSIBLE FOR PLACING THE
GROMMET DURING THE PROCESS. THE WIRING IS COMPLETED DURING THE PRODUCTION PROCESS AND
NOT WHEN THE AIR CONDITIONER IS INSTALLED ON THE ROOF.
Description of Remedy :
Description of Remedy Program : DEALERS WITH INVENTORY WILL BE SENT A SOP (STANDARD
OPERATING PROCEDURE) TO INSTALL A GROMMET WITH 2 SCREWS.
DEALERS WILL SUBMIT A WARRANTY CLAIM FOR REIMBURSEMENT.
RETAIL OWNERS WILL BE SENT THE SOP(STANDARD OPERATING
PROCEDURE), GROMMET & 2 SCREWS TO HAVE INSTALLED BY AN RV
SERVICE CENTER. THE RV SERVICE CENTER OR RETAIL OWNER WILL BE
PAID DIRECTLY BY TRIPLE E RV. AN RV SERVICE CENTER OR RETAIL
OWNER WILL BE REIMBURSED FOR COSTS INCURRED FOR REPAIR
PRIOR TO THE RECALL NOTIFICATION.
How Remedy Component Differs
from Recalled Component :
THE ALUMINUM FRAMING LOCATED AT THE AIR CONDITIONER WILL
HAVE A GROMMET INSTALLED ON THE METAL EDGE OF THE ACCESS
HOLE WITH THE 120V WIRING RUNING THROUGH IT. THE RECALLED
UNITS WILL NOT HAVE A GROMMET INSTALLED.
Identify How/When Recall Condition
was Corrected in Production :
ON OCTOBER 25/2023 THE INSTALLERS WERE NOTIFIED TO CHECK ALL
WONDER MODELS THAT HAVE THE TRUMA AIR CONDITIONER 120V
WIRING INSTALLED DURING THE PRODUCTION PROCESS AND INSTALL
THE GROMMET WITH 2 SCREWS AND HAVE THE WIRING ROUTED
THROUGH IT . THE DRAWINGS WILL BE UPDATED SHOWING THE
WIRING CHANNEL BY EARLY JANUARY /2024 & THE SOP WILL BE
CREATED FOR THE INSTALLERS TO FOLLOW BY MID DECEMBER 2023
THERE WILL BE NO MISCOMMUNICATION ON WHO IS TO INSTALL THE
GROMMET AND AT WHAT POINT IN THE PRODUCTION PROCESS.
Recall Schedule :
Description of Recall Schedule : NOTIFICATION TO THE DEALERS IS EXPECTED TO OCCUR ABOUT NOV.
Part 573 Safety Recall Report 23V-766 Page 4
The information contained in this report was submitted pursuant to 49 CFR §573
21/2023. NOTIFICATION TO THE RETAIL OWNERS IS EXPECTED TO
OCCUR ABOUT NOV. 21/2023
Planned Dealer Notification Date : NOV 21, 2023 – NOV 28, 2023
Planned Owner Notification Date : NOV 21, 2023 – NOV 28, 2023
Purchaser Information :
The following manufacturers purchased this defective/noncompliant equipment for possible use or
installation in new motor vehicles or new items of motor vehicle equipment:
Name :
Address :
Country :
Company Phone :
* NR – Not Reported
**************************************************************************************************************
OMB Control No.: 2127-0004
Part 573 Safety Recall Report 23V-766
The information contained in this report was submitted pursuant to 49 CFR §573
Manufacturer Name : Triple E Recreational Vehicles
Submission Date : NOV 20, 2023
NHTSA Recall No. : 23V-766
Manufacturer Recall No. : CA#10438-1
Manufacturer Information :
Manufacturer Name : Triple E Recreational Vehicles
Address : PO Box 1230 Winkler MB
Canada 00 R6W 4C4
Company phone : 204-325-4361
Population :
Number of potentially involved : 37
Estimated percentage with defect : 100 %
Vehicle Alterer Information :
Vehicle 1 : 2023-2024 WONDER W24RTB
Descriptive Information : CERTAIN WONDER MODELS HAVE THE TRUMA AIR CONDITIONER INSTALLED
ON THE ROOF DURING THE SUB-ASSEMBLY PROCESS AND THE WIRING
CONNECTIONS ARE COMPLETED ON THE PRODUCTION LINE, THEY DON’T
HAVE DUCTED AIR CONDITIONER ROOF VENTS. THE OTHER MODEL IS
INSTALLED AND WIRING CONNECTIONS COMPLETED ON THE PRODUCTION
LINE, HAVING DUCTED AIR CONDITIONER ROOF VENTS.
UNITS AFFECTED 20
Production Dates : MAY 05, 2023 – OCT 18, 2023
Vehicle 2 : 2023-2024 WONDER W24RL
Descriptive Information : CERTAIN WONDER MODELS HAVE THE TRUMA AIR CONDITIONER INSTALLED
ON THE ROOF DURING THE SUB-ASSEMBLY PROCESS AND THE WIRING
CONNECTIONS ARE COMPLETED ON THE PRODUCTION LINE, THEY DON’T
HAVE DUCTED AIR CONDITIONER ROOF VENTS. THE OTHER MODEL IS
INSTALLED AND WIRING CONNECTIONS COMPLETED ON THE PRODUCTION
LINE, HAVING DUCTED AIR CONDITIONER ROOF VENTS.
UNITS AFFECTED 12
Production Dates : MAY 05, 2023 – OCT 18, 2023
Part 573 Safety Recall Report 23V-766 Page 2
The information contained in this report was submitted pursuant to 49 CFR §573
Vehicle 3 : 2023-2024 WONDER W24FTB
Descriptive Information : CERTAIN WONDER MODELS HAVE THE TRUMA AIR CONDITIONER INSTALLED
ON THE ROOF DURING THE SUB-ASSEMBLY PROCESS AND THE WIRING
CONNECTIONS ARE COMPLETED ON THE PRODUCTION LINE, THEY DON’T
HAVE DUCTED AIR CONDITIONER ROOF VENTS. THE OTHER MODEL IS
INSTALLED AND WIRING CONNECTIONS COMPLETED ON THE PRODUCTION
LINE, HAVING DUCTED AIR CONDITIONER ROOF VENTS.
UNITS AFFECTED 5
Production Dates : MAY 05, 2023 – OCT 18, 2023
Description of Defect :
Description of the Defect : THE 120V WIRING ROUTED TO THE TRUMA AIR CONDITIONER THROUGH
THE ALUMINUM ROOF FRAME MAY NOT HAVE A GROMMET TO PROTECT
FROM THE RAW METAL EDGE.
FMVSS 1 : NR
FMVSS 2 : NR
Description of the Safety Risk : THE WIRE INSULATION MAY BECOME WORN FROM RUBBING ON THE
METAL EDGE OF THE ALUMINUM TUBING, CAUSING AN ARCING HAZARD.
THIS COULD CAUSE A SMALL SPARK, AND CAUSE A POSSIBLE FIRE AND
BODILY INJURY.
Description of the Cause : DURING A CHANGE FROM MODEL YEAR THE ROOF DRAWINGS HAD THE
WIRE CHANNELS ACCIDENTLY OMITTED. THE INSTALLER OF THE WIRING
WAS NOT AWARE THAT A GROMMET HAD TO BE INSTALLED ON THE METAL
EDGE OF THE ALUMINUM TUBING TO PROTECT THE WIRING.
Identification of Any Warning
that can Occur :
THERE COULD BE A POSSIBLE SMELL OF WIRE INSULATION BURNING OR
THE TRUMA AIR CONDITIONER WILL NOT HAVE POWER.
Involved Components :
Component Name : NR
Component Description : NR
Component Part Number : NR
Supplier Identification :
Component Manufacturer
Part 573 Safety Recall Report 23V-766 Page 3
The information contained in this report was submitted pursuant to 49 CFR §573
Name : NR
Address : NR
NR
Country : NR
Chronology :
ON OCTOBER 25/2023 AN INHOUSE AUDIT WAS CONDUCTED IT WAS NOTICED THAT THE TRUMA AIR
CONDITIONER 120V WIRING WAS WIRED THROUGH THE ALUMINUM ROOF FRAME WITH NO PROTECTION
FROM THE METAL EDGE. THE ROOF DRAWINGS DID NOT INCLUDE THE WIRING CHANNELS FOR THE
INSTALLER TO FOLLOW CAUSING INCONSISTENCIES IN THE INSTALLATION PROCEDURE OF THE WIRING
FOR THE AIR CONDITIONER. A MISCOMMUNICATION ON WHO WAS RESPONSIBLE FOR PLACING THE
GROMMET DURING THE PROCESS. THE WIRING IS COMPLETED DURING THE PRODUCTION PROCESS AND
NOT WHEN THE AIR CONDITIONER IS INSTALLED ON THE ROOF.
Description of Remedy :
Description of Remedy Program : DEALERS WITH INVENTORY WILL BE SENT A SOP (STANDARD
OPERATING PROCEDURE) TO INSTALL A GROMMET WITH 2 SCREWS.
DEALERS WILL SUBMIT A WARRANTY CLAIM FOR REIMBURSEMENT.
RETAIL OWNERS WILL BE SENT THE SOP(STANDARD OPERATING
PROCEDURE), GROMMET & 2 SCREWS TO HAVE INSTALLED BY AN RV
SERVICE CENTER. THE RV SERVICE CENTER OR RETAIL OWNER WILL BE
PAID DIRECTLY BY TRIPLE E RV. AN RV SERVICE CENTER OR RETAIL
OWNER WILL BE REIMBURSED FOR COSTS INCURRED FOR REPAIR
PRIOR TO THE RECALL NOTIFICATION.
How Remedy Component Differs
from Recalled Component :
THE ALUMINUM FRAMING LOCATED AT THE AIR CONDITIONER WILL
HAVE A GROMMET INSTALLED ON THE METAL EDGE OF THE ACCESS
HOLE WITH THE 120V WIRING RUNING THROUGH IT. THE RECALLED
UNITS WILL NOT HAVE A GROMMET INSTALLED.
Identify How/When Recall Condition
was Corrected in Production :
ON OCTOBER 25/2023 THE INSTALLERS WERE NOTIFIED TO CHECK ALL
WONDER MODELS THAT HAVE THE TRUMA AIR CONDITIONER 120V
WIRING INSTALLED DURING THE PRODUCTION PROCESS AND INSTALL
THE GROMMET WITH 2 SCREWS AND HAVE THE WIRING ROUTED
THROUGH IT . THE DRAWINGS WILL BE UPDATED SHOWING THE
WIRING CHANNEL BY EARLY JANUARY /2024 & THE SOP WILL BE
CREATED FOR THE INSTALLERS TO FOLLOW BY MID DECEMBER 2023
THERE WILL BE NO MISCOMMUNICATION ON WHO IS TO INSTALL THE
GROMMET AND AT WHAT POINT IN THE PRODUCTION PROCESS.
Recall Schedule :
Description of Recall Schedule : NOTIFICATION TO THE DEALERS IS EXPECTED TO OCCUR ABOUT NOV.
Part 573 Safety Recall Report 23V-766 Page 4
The information contained in this report was submitted pursuant to 49 CFR §573
21/2023. NOTIFICATION TO THE RETAIL OWNERS IS EXPECTED TO
OCCUR ABOUT NOV. 21/2023
Planned Dealer Notification Date : NOV 21, 2023 – NOV 28, 2023
Planned Owner Notification Date : NOV 21, 2023 – NOV 28, 2023
Purchaser Information :
The following manufacturers purchased this defective/noncompliant equipment for possible use or
installation in new motor vehicles or new items of motor vehicle equipment:
Name :
Address :
Country :
Company Phone :
* NR – Not Reported
**************************************************************************************************************
OMB Control No.: 2127-0004
Part 573 Safety Recall Report 23V-766
The information contained in this report was submitted pursuant to 49 CFR §573
Manufacturer Name : Triple E Recreational Vehicles
Submission Date : NOV 15, 2023
NHTSA Recall No. : 23V-766
Manufacturer Recall No. : CA#10438-1
Manufacturer Information :
Manufacturer Name : Triple E Recreational Vehicles
Address : PO Box 1230 Winkler MB
Canada 00 R6W 4C4
Company phone : 204-325-4361
Population :
Number of potentially involved : 37
Estimated percentage with defect : 100 %
Vehicle Alterer Information :
Vehicle 1 : 2023-2024 WONDER W24RTB
Descriptive Information : CERTAIN WONDER MODELS HAVE THE TRUMA AIR CONDITIONER INSTALLED
ON THE ROOF DURING THE SUB-ASSEMBLY PROCESS AND THE WIRING
CONNECTIONS ARE COMPLETED ON THE PRODUCTION LINE, THEY DON’T
HAVE DUCTED AIR CONDITIONER ROOF VENTS. THE OTHER MODEL IS
INSTALLED AND WIRING CONNECTIONS COMPLETED ON THE PRODUCTION
LINE, HAVING DUCTED AIR CONDITIONER ROOF VENTS.
UNITS AFFECTED 20
Production Dates : MAY 05, 2023 – OCT 18, 2023
Vehicle 2 : 2023-2024 WONDER W24FTB
Descriptive Information : CERTAIN WONDER MODELS HAVE THE TRUMA AIR CONDITIONER INSTALLED
ON THE ROOF DURING THE SUB-ASSEMBLY PROCESS AND THE WIRING
CONNECTIONS ARE COMPLETED ON THE PRODUCTION LINE, THEY DON’T
HAVE DUCTED AIR CONDITIONER ROOF VENTS. THE OTHER MODEL IS
INSTALLED AND WIRING CONNECTIONS COMPLETED ON THE PRODUCTION
LINE, HAVING DUCTED AIR CONDITIONER ROOF VENTS.
UNITS AFFECTED 5
Production Dates : MAY 05, 2023 – OCT 18, 2023
Part 573 Safety Recall Report 23V-766 Page 2
The information contained in this report was submitted pursuant to 49 CFR §573
Vehicle 3 : 2023-2024 WONDER W24RL
Descriptive Information : CERTAIN WONDER MODELS HAVE THE TRUMA AIR CONDITIONER INSTALLED
ON THE ROOF DURING THE SUB-ASSEMBLY PROCESS AND THE WIRING
CONNECTIONS ARE COMPLETED ON THE PRODUCTION LINE, THEY DON’T
HAVE DUCTED AIR CONDITIONER ROOF VENTS. THE OTHER MODEL IS
INSTALLED AND WIRING CONNECTIONS COMPLETED ON THE PRODUCTION
LINE, HAVING DUCTED AIR CONDITIONER ROOF VENTS.
UNITS AFFECTED 12
Production Dates : MAY 05, 2023 – OCT 18, 2023
Description of Defect :
Description of the Defect : THE 120V WIRING ROUTED TO THE TRUMA AIR CONDITIONER THROUGH
THE ALUMINUM ROOF FRAME MAY NOT HAVE A GROMMET TO PROTECT
FROM THE RAW METAL EDGE.
FMVSS 1 : NR
FMVSS 2 : NR
Description of the Safety Risk : THE WIRE INSULATION MAY BECOME WORN FROM RUBBING ON THE
METAL EDGE OF THE ALUMINUM TUBING, CAUSING AN ARCING HAZARD.
THIS COULD CAUSE A SMALL SPARK, AND CAUSE A POSSIBLE FIRE AND
BODILY INJURY.
Description of the Cause : DURING A CHANGE FROM MODEL YEAR THE ROOF DRAWINGS HAD THE
WIRE CHANNELS ACCIDENTLY OMITTED. THE INSTALLER OF THE WIRING
WAS NOT AWARE THAT A GROMMET HAD TO BE INSTALLED ON THE METAL
EDGE OF THE ALUMINUM TUBING TO PROTECT THE WIRING.
Identification of Any Warning
that can Occur :
THERE COULD BE A POSSIBLE SMELL OF WIRE INSULATION BURNING OR
THE TRUMA AIR CONDITIONER WILL NOT HAVE POWER.
Involved Components :
Component Name : NR
Component Description : NR
Component Part Number : NR
Supplier Identification :
Component Manufacturer
Part 573 Safety Recall Report 23V-766 Page 3
The information contained in this report was submitted pursuant to 49 CFR §573
Name : NR
Address : NR
NR
Country : NR
Chronology :
ON OCTOBER 25/2023 AN INHOUSE AUDIT WAS CONDUCTED IT WAS NOTICED THAT THE TRUMA AIR
CONDITIONER 120V WIRING WAS WIRED THROUGH THE ALUMINUM ROOF FRAME WITH NO PROTECTION
FROM THE METAL EDGE. THE ROOF DRAWINGS DID NOT INCLUDE THE WIRING CHANNELS FOR THE
INSTALLER TO FOLLOW CAUSING INCONSISTENCIES IN THE INSTALLATION PROCEDURE OF THE WIRING
FOR THE AIR CONDITIONER. A MISCOMMUNICATION ON WHO WAS RESPONSIBLE FOR PLACING THE
GROMMET DURING THE PROCESS. THE WIRING IS COMPLETED DURING THE PRODUCTION PROCESS AND
NOT WHEN THE AIR CONDITIONER IS INSTALLED ON THE ROOF.
Description of Remedy :
Description of Remedy Program : DEALERS WITH INVENTORY WILL BE SENT A SOP (STANDARD
OPERATING PROCEDURE) TO INSTALL A GROMMET WITH 2 SCREWS.
DEALERS WILL SUBMIT A WARRANTY CLAIM FOR REIMBURSEMENT.
RETAIL OWNERS WILL BE SENT THE SOP(STANDARD OPERATING
PROCEDURE), GROMMET & 2 SCREWS TO HAVE INSTALLED BY AN RV
SERVICE CENTER. THE RV SERVICE CENTER OR RETAIL OWNER WILL BE
PAID DIRECTLY BY TRIPLE E RV. AN RV SERVICE CENTER OR RETAIL
OWNER WILL BE REIMBURSED FOR COSTS INCURRED FOR REPAIR
PRIOR TO THE RECALL NOTIFICATION.
How Remedy Component Differs
from Recalled Component :
THE ALUMINUM FRAMING LOCATED AT THE AIR CONDITIONER WILL
HAVE A GROMMET INSTALLED ON THE METAL EDGE OF THE ACCESS
HOLE WITH THE 120V WIRING RUNING THROUGH IT. THE RECALLED
UNITS WILL NOT HAVE A GROMMET INSTALLED.
Identify How/When Recall Condition
was Corrected in Production :
ON OCTOBER 25/2023 THE INSTALLERS WERE NOTIFIED TO CHECK ALL
WONDER MODELS THAT HAVE THE TRUMA AIR CONDITIONER 120V
WIRING INSTALLED DURING THE PRODUCTION PROCESS AND INSTALL
THE GROMMET WITH 2 SCREWS AND HAVE THE WIRING ROUTED
THROUGH IT . THE DRAWINGS WILL BE UPDATED SHOWING THE
WIRING CHANNEL BY EARLY JANUARY /2024 & THE SOP WILL BE
CREATED FOR THE INSTALLERS TO FOLLOW BY MID DECEMBER 2023
THERE WILL BE NO MISCOMMUNICATION ON WHO IS TO INSTALL THE
GROMMET AND AT WHAT POINT IN THE PRODUCTION PROCESS.
Recall Schedule :
Description of Recall Schedule : NOTIFICATION TO THE DEALERS IS EXPECTED TO OCCUR ABOUT NOV.
Part 573 Safety Recall Report 23V-766 Page 4
The information contained in this report was submitted pursuant to 49 CFR §573
21/2023. NOTIFICATION TO THE RETAIL OWNERS IS EXPECTED TO
OCCUR ABOUT NOV. 21/2023
Planned Dealer Notification Date : NOV 21, 2023 – NOV 28, 2023
Planned Owner Notification Date : NOV 21, 2023 – NOV 28, 2023
Purchaser Information :
The following manufacturers purchased this defective/noncompliant equipment for possible use or
installation in new motor vehicles or new items of motor vehicle equipment:
Name :
Address :
Country :
Company Phone :
* NR – Not Reported
**************************************************************************************************************
**************************************************************************************************************
**************************************************************************************************************